5-12
1-2-2.
INITIALIZATION OF B PAGE DATA
Note 1:
When reading the B page data, insert a “Memory Stick” into the
“Memory Stick” slot.
Note 2:
“INITIALIZATION OF B PAGE DATA” should be carried out
upon completion of “INITIALIZATION OF C, D, 8 PAGE DATA”.
Switch setting:
POWER ................................................................. MEMORY
1. Initializing the B Page Data
Note:
If the B page data has been initialized, the following adjustments
need to be performed again.
1) Modification of B page data
Adjusting page
B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
8F
02
Set the data, and press PAUSE button.
3
2
8F
03
Set the data, and press PAUSE button.
4
2
8F
02
Set the data, and press PAUSE button.
5
2
8F
00
Set the data, and press PAUSE button.
6
5
0E
00
Set the data.
7
5
01
F3
Set the data, and press PAUSE button.
8
5
00
01
Set the data, and press PAUSE button.
9
Wait for 3 sec.
10
5
0E
Check that the data is “01”.
11
5
02
01
Set the data, and press PAUSE button.
12
5
01
FE
Set the data, and press PAUSE button.
13
5
00
01
Set the data, and press PAUSE button.
14
5
02
Check that the data.
When the data is “00”, proceed
to step 19.
When the data is “FF”, proceed
to step 15.
15
2
0E
00
Set the data, and press PAUSE button.
16
5
01
FD
Set the data, and press PAUSE button.
17
5
00
01
Set the data, and press PAUSE button.
18
5
0E
Check that the data is “01”.
19
5
01
FA
Set the data, and press PAUSE button.
20
5
03
20
Set the data, and press PAUSE button.
21
5
00
01
Set the data, and press PAUSE button.
22
5
0E
Check that the data is “01”.
23
Perform “Modification of B
Page Data”.
2. Modification of B Page Data
If the B page data has been initialized, change the data of the “Fixed
data-2” address shown in the following tables by manual input.
Preparations:
Order Page Address Data
Procedure
1
2
8F
02
Set the data, and press PAUSE button.
2
2
8F
03
Set the data, and press PAUSE button.
3
2
8F
02
Set the data, and press PAUSE button.
4
2
8F
00
Set the data, and press PAUSE button.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of B Page data:
Order Page Address Data
Procedure
1
2
00
29
Set the data.
2
2
01
29
Set the data, and press PAUSE button.
3. B  Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the B Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of B Page Data”).
Address
00 to FF
Remark
Fixed data-1
Table. 5-1-5.
Page of 127