DCR-TRV250 (serv.man4) - Sony Movie Service Manual (repair manual). Page 11

Read Sony DCR-TRV250 (serv.man4) Service Manual online

DCR-TRV250
6-9
COVER
COVER
1-2.
INITIALIZATION  OF  8,  A,  B,  C,  D,  E,  F, 18,
1B,  1C,  1F  PAGE  DATA
Note:
If reading/writing data on pages 18, 1B, 1C, 1F, set data:
01 to page: 0, address: 10, and then select pages 8, B, C, F.
By this data setting, the pages 18, 1B, 1C, 1F can be se-
lected.
After the data reading/writing finished, return the data on
page: 0, address: 10 to “00”.
1-2-1.
Initialization of A, D Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing the A, D Page Data
Note 1:
If “Initialization of Pages A, D” is executed, all data on
pages A, D are initialized. (Only an individual page can-
not be initialized)
Note 2:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1)  Modification of A, D page data
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
D
Adjustment Address
10 to FF
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
03
01
4
7
00
28
5
7
01
28
Press PAUSE button.
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
D Page Data”
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of
the“Fixed data-2” address shown in the following table by manual
input.
Modifying Method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification A, D page data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Note 2:
If the following symptoms occur after completing of
the“Modification A, D page data”, check that the data of
the “Fixed data-2” addresses of A, D page are same as
those of the same model of the same destination.
1) The power is shut off so that unit cannot operate.
Page of 67
Display

Click on the first or last page to see other DCR-TRV250 (serv.man4) service manuals if exist.