DCR-TRV22, DCR-TRV22E (serv.man4) - Sony Movie Service Manual (repair manual). Page 11

Read Sony DCR-TRV22 / DCR-TRV22E (serv.man4) Service Manual online

6-8
DCR-TRV22/TRV22E
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 1B,
1C, 1F PAGE DATA
Note:
When reading or writing the 18, 1B, 1C or 1F page data, select
page: 0, address: 10, and set data: 01, then select 8, B, C or F page.
The 18, 1B, 1C or 1F page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
[Connection of the power supply during the initialization
of the data.]
1)
Connect the regulated power supply and the digital voltmeter
to the battery terminal as shown in Fig. 6-1-6.
2)
Adjust the output voltage of the regulated power supply so that
the digital voltmeter display is 6.0 ± 0.1Vdc.
3)
Turn off the power supply.
4)
Turn on the HOLD switch of the adjusting remote commander.
5)
Turn on the power supply.
6)
Perform the initialization of the data.
Note:
This is normal though the following message is indicated on
the LCD screen.
   “FOR InfoLITHIUM BATTERY ONLY”
[Initialization Procedure]
1.
Initialization of A, D page data
2.
Initialization of B, 1B page data
3.
Initialization of 8, C, 18, 1C page data
4.
Initialization of E, F, 1F page data
COVER
COVER
Regulated power supply
Battery terminal
Digital volt meter
Fig. 6-1-6.
Page of 67