DCR-TRV15E, DCR-TRV17E (serv.man2) - Sony Movie Service Manual (repair manual). Page 113

Read Sony DCR-TRV15E / DCR-TRV17E (serv.man2) Service Manual online

5-5
Fig. 5-1-2.
1-1-2.
Preparations
Note 1:
For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-2.
Note 3:
As removing the cabinet (R) (removing the VC-260 board CN009)
means removing the lithium 3V power supply (BT8301), data such
as date, time, user-set menus will be lost. After completing
adjustments, reset these data. If the cabinet (R) has been removed,
the self-diagnosis data, data on history of use (total drum rotation
time etc. ) will be lost. Before removing, note down the data of
page: 2, address: A2 to AA (data on history of use) and the data of
page: 2, address: B0 to C6 (self-diagnosis data). (Refer to “5-
4.Service Mode” for the data on the history use and the self-
diagnosis data.)
Note 4:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (PS-1700) removed. After
completing adjustments, be sure to exit the “Forced Camera Power
ON Mode”.
Note 5:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
1.5 m
Front of the lens
Pattern box
Page of 127