5-7
Fig. 5-1-2.
1.5m
Pattern Box
Front of the lens
1-1-2.
Preparations
Note 1:
For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note 2:
When performing only the adjustments, the lens block and boards
need not be disassembled.
1)
Connect the equipment for adjustments according to Fig. 5-1-2.
Note 3:
As removing the cabinet (R) (removing the VC-240/241 board
CN003) means removing the lithium 3V power supply (BT3201),
data such as date, time, user-set menus will be lost. After
completing adjustments, reset these data. If the cabinet (R) has
been removed, the self-diagnosis data, data on history of use (total
drum rotation time etc. ) will be lost. Before removing, note down
the self-diagnosis data and the data on history use (data of page:
2, address: A2 to AA). (Refer to “SELF-DIAGNOSIS
FUNCTION” for the self-diagnosis data, and to “5-4.Service
Mode” for the data on the history use.)
Note 4:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button of the adjustment remote commander.
The above procedure will enable the camera power to be turned
on with the control switch block (FK-30150) removed. After
completing adjustments, be sure to exit the “Forced Camera Power
ON Mode”.
Note 5:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button of the adjustment remote commander.
3) Select page: 0, address: 01, and set data: 00.
Page of 127