5-18
4. Flange Back Check
Subject
Siemens star (PTB-450)
(2.0 m from the front of the lens)
(Luminance : approx. 200 lux)
Measurement Point
Check operation on TV monitor
Measuring Instrument
Specified Value
Focused at the TELE end and WIDE end.
Switch setting:
1)
NIGHT SHOT .................................................................. OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
Note:
When the auto focus is ON, the lens can be checked if
it is focused or not by observing the data on the page 1
of the adjustment remote commander.
1) Select page: 0, address: 03, and set data: 0F.
2) Page 1 shows the state of the focus.
1 : 00 : XX
Odd: Focused
Even: Unfocused
Checking method:
1)
Place the Siemens star 2.0 m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the
Siemens star up to a point before noise appear on the image.
3)
Select page: 6, address: 40, and set data: 02.
4)
Select page: 6, address: 41, and set data: 01.
5)
Shoot the Siemens star with the zoom TELE end.
6)
Turn on the auto focus.
7)
Check that the lens is focused (Note).
8)
Select page: 6, address: 21, and set data: 10.
9)
Shoot the Siemens star with the zoom WIDE end.
10) Observe the TV monitor and check that the lens is focused.
Processing after Completing Adjustments
1)
Select page: 6, address: 21, and set data: 00.
2)
Select page: 6, address: 40, and set data: 00.
3)
Select page: 6, address: 41, and set data: 00.
4)
Select page: 0, address: 03, and set data: 00.