DCR-TR8000E, DCR-TR8100E, DCR-TRV120, DCR-TRV120E, DCR-TRV120P, DCR-TRV125E - Sony Movie Service Manual (repair manual). Page 109

Read Sony DCR-TR8000E / DCR-TR8100E / DCR-TRV120 / DCR-TRV120E / DCR-TRV120P / DCR-TRV125E Service Manual online

5-9
1-2.
INITIALIZATION OF 7, 8, C, D, E, F PAGE
DATA
1-2-1. INITIALIZATION OF 8, C, D PAGE DATA
1. Initializing the 8, C, D Page Data
Note1:
If “Initialization of Pages 8, C, D” is executed, all data on
pages 8, C and D are initialized. (Only an individual page
cannot be initialized)
Note2:
If the 8, C, D page data has been initialized, “Modification
of 8, C, D Page Data” and following adjustments need to
be performed again.
1)
LCD system adjustment
2)
System control system adjustment
3)
Servo and RF system adjustment
4)
“Chroma BPF f
0
 adjustment”,  “S VIDEO OUT Y level
adjustment” and “S VIDEO OUT chroma level adjustment” of
the video system adjustments.
Adjusting Page
8
Adjusting Address
00 to FF
Adjusting Page
C
Adjusting Address
10 to FF
Adjusting Page
D
Adjusting Address
10 to FF
Initializing Method:
1)
Select page: 0, address: 01, and set data: 80.
2)
Select page: 3, address: 81, set data: 10, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 3, address: 80, set data: 0A, and press the PAUSE
button of the adjustment remote commander.
4)
Select page: 3, address: 80, and check that the data changes to
“1A”.
5)
Select page: D, address: 2D, set data: 00, and press the PAUSE
button of the adjustment remote commander.
6)
Select page: 0, address: 01, and set data: 00.
7)
Perform “Modification of 8, C, D Page Data”.
2. Modification of 8, C, D Page Data
If the 8, C, D page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note :
If copy the data built in the different model, the camcorder
may not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D Page data
1)
Select page: 2, address: 00, and set data: 29.
2)
Select page: 2, address: 01, and set data: 29, and press the
PAUSE button of the adjustment remote commander.
3)
Select page: 0, address: 01, and set data: 00.
Address
Initial value
Remark
NTSC PAL
00 to 98
Fixed data-1 (Initialized data)
99
Fixed data-2
9A to A2
Fixed data-1 (Initialized data)
A3
Fixed data-2
A4 to FF
Fixed data-1 (Initialized data)
3. 8 Page Table
Note1:
Fixed data-1: Initialized data. (Refer to “1. Initializing the
8, C, D Page Data”)
Note2:
Fixed data-2: Modified data. (Refer to “2. Modified of 8,
C, D Page Data”)
Page of 127
Display