DCR-SX45/SX45E/SX65/SX65E/SX85/SX85E_L2
1-2E
1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block 
Function
Detailed 
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or replace it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the Memory card.
Insert a new Memory card.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus).
Inspect the lens block focus reset sensor (pin 8 of CN1003 on the 
VC-616 board) when focusing is performed when the focus button is 
pressed in the focus manual mode, and the focus motor drive circuit 
(IC5401 on the VC-616 board) when the focusing is not performed.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens).
Inspect the lens block zoom reset sensor (pin 0 of CN1003 on the 
VC-616 board) when zooming is performed when the zoom lever is 
operated, or the zoom motor drive circuit (IC5401 on the VC-616 
board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of the 
zoom lens occurred simultaneously.
Check both E: 61: 00 and E: 61: 10 of the self-diagnosis code.
E
6
2
0
0
Handshake correction function does not 
work well. (With PITCH angular velocity 
sensor output stopped.)
Inspect PITCH angular velocity sensors (SE9301 on the MS-453
board) peripheral circuits.
E
6
2
0
1
Handshake correction function does not 
work well. (With YAW angular velocity 
sensor output stopped.)
Inspect YAW angular velocity sensors (SE9301 on the MS-453 board) 
peripheral circuits.
E
9
2
0
1
Battery current value goes over the max 
discharge current.
Check the remaining battery power because this symptom may be 
depended on the remaining battery level, and confirm whether or not 
the symptom is occurred after replacing the battery. If the symptom 
is still occurred, overhaul inspection is needed. Check each output of  
DC-DC converter (IC4701) on the VC-616 board with the AC adaptor 
connected to DC JACK (J901) on the VC-616 board. (the minimum 
connection to periphery) 
E
9
4
0
0
Fault of writing to or erasing the flash memory. Inspect the flash memory (IC7801 on the VC-616 board).
E
9
4
0
1
Internal flash memory fault.
Inspect the flash memory (IC7801 on the VC-616 board).