1-3-3. Self-diagnosis Code Table
Self-diagnosis Code
Symptom/State
Correction
Repaired by:
Block 
Function
Detailed 
Code
C
0
4
0
0
Non-standard battery is used.
Use the InfoLITHIUM battery.
C
0
6
0
0
The battery pack temperature is high.
Change the battery pack or replace it in a cool place.
C
1
3
0
1
Memory card is unformatted.
Memory card is broken.
Format the Memory card.
Insert a new Memory card.
C
1
3
0
2
Disc access error.
Remove the power source. Reconnect it again and operate your 
camcorder again.
E
2
0
0
0
Flash memory data are rewritten.
Make flash memory data correct value. (Note 1)
E
3
1
0
0
Drive fault
Turn power off and turn power on again.
E
6
1
0
0
Difficult to adjust focus
(Cannot initialize focus).
Inspect the lens block focus reset sensor (pin 8 of CN5401 on the 
VC-611 (F) /(H) board) when focusing is performed when the focus 
button is pressed in the focus manual mode, and the focus motor drive 
circuit (IC5401 on the VC-611 (F) /(H) board) when the focusing is 
not performed.
E
6
1
1
0
Zoom operations fault
(Cannot initialize zoom lens).
Inspect the lens block zoom reset sensor (pin 0 of CN5401 on the 
VC-611 (F) /(H) board) when zooming is performed when the zoom 
lever is operated, or the zoom motor drive circuit (IC5401 on the VC-
611 (F) /(H) board) when zooming is not performed.
E
6
1
1
1
The abnormalities in initialization of the focus 
lens and the abnormalities in initialization of the 
zoom lens occurred simultaneously.
Check both E: 61: 00 and E: 61: 10 of the self-diagnosis code.
E
9
2
0
1
Battery current value goes over the max 
discharge current.
Check the remaining battery power because this symptom may be 
depended on the remaining battery level, and confirm whether or not 
the symptom is occurred after replacing the battery. If the symptom 
is still occurred, overhaul inspection is needed. Check each output of  
DC-DC converter (IC4701) on the VC-611 (F) /(H) board with the AC 
adaptor connected to DC JACK (J901) on the VC-611 (F) /(H) board. 
(the minimum connection to periphery) 
E
9
4
0
0
Fault of writing to or erasing the flash memory. Inspect the flash memory (IC7801 on the VC-611 (F) /(H) board).
Note 1 : Start the Adjust Manual in the Adjust Station and refer to the “DESTINATION DATA WRITE”.