1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 18, 19,
1A, 1B, 1C, 1E, 1F PAGE DATA
Note: When reading or writing the  18, 19, 1A, 1B, 1C, 1E or 1F page
data, select page: 0, address: 10, and set data: 01, then select 8, 9, A,
B, C, E or F page. The 18, 19, 1A, 1B, 1C 1E, or 1F page can be
chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1-2-1. INITIALIZATION OF A, B, D, 1A, 1B PAGE DATA
Note: When reading or writing the A, B, D page data, select page: 0,
address: 10, and set data: 00.
When reading or writing the 1A or 1B page data, select page: 0,
address: 10, and set data: 01, then select A or B page. The 1A or 1B
page can be chosen by this data setting.
After reading or writing, reset the data of page: 0, address: 10 to
“00”.
1. Initializing the A, B, D, 1A, 1B Page Data
Note1: If the A, B, D, 1A, 1B page data has been initialized, the following
adjustments need to be performed again.
1) Modification of A, B, D, 1A, 1B page data
2) Touch panel adjustment
Adjusting page
A
Adjusting Address
10 to FF
Adjusting page
B
Adjusting Address
00 to FF
Adjusting page
D
Adjusting Address
10 to 7F
Adjusting page
1A
Adjusting Address
00 to FF
Adjusting page
1B
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
7
04
Set the following data.
40 (DCR-PC55 (NTSC))
41 (DCR-PC53E/PC55E (PAL))
4
7
01
XX
Set the data. (Note)
5
7
00
01
Set the data, and press PAUSE
button.
6
7
02
Check that the data changes to
“01”
7
Perform “Modification of A, B,
D, 1B Page Data”.
Note: XX=20: Initializing A page
XX=21: Initializing B page
XX=22: Initializing D page
XX=23: Initializing 1A page
XX=24: Initializing 1B page
XX=25: Initializing A and 1A pages
XX=26: Initializing B and 1B pages
XX=28: Initializing A, B, D, 1A and 1B pages
2. Modification of A, B, D, 1A, 1B Page Data
If the A, B, D, 1A, 1B page data has been initialized, change the
data of the “Fixed data-2” address shown in the following tables by
manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
When changing the A, B, D page data, select page: 0, address:
10, and set data: 00.
3)
When changing the 1A, 1B page data, select page: 0, address:
10, and set data: 01.
After completing the modification of 1A, 1B page data, reset
the data of this address to “00”.
4)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note: If copy the data built in the different model, the camcorder may
not operate.
5)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
Processing after Completing Modification of A, B, D, 1A, 1B
Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
Note: If the following symptoms occur after completing of the
“Modification of A, B, D, 1A, 1B page data”, check that the data of
addresses: 1A to 4F of A page and the data of addresses: 12 to 19 of
D page are same as those of the same model of the same destination.
1) The self-diagnosis code “E:20:00” on the LCD screen is displayed.
2) The power is shut off so that unit cannot operate.