DCR-PC53E, DCR-PC55, DCR-PC55E (serv.man4) - Sony Movie Service Manual (repair manual). Page 34

Read Sony DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) Service Manual online

6-32
DCR-PC53E/PC55/PC55E
15. MAX GAIN Adjustment
Setting the minimum illumination.
If it is not consistent, the image level required for taking subjects in
low illuminance will not be produced (dark).
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
19
Note1: This adjustment should be carried out upon completion of “Flange
back adjustment” and “Optical Axis Adjustment”.
Note2: The data of page: 0, address: 10 must be “00”.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Note4: NTSC model : DCR-PC55
PAL model
: DCR-PC53E/PC55E
Switch setting:
1)
POWER ....................................................... CAMERA-TAPE
2)
DIGITAL ZOOM (Menu setting) .................................... OFF
3)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
96
Set the following data.
25 (NTSC), 1A(PAL)
4
6
97
Set the following data.
80 (NTSC), C0(PAL)
5
6
01
6F
Set the data, and press PAUSE
button.
6
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
19.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
48
00
Set the data.
2
6
96
00
Set the data.
3
6
97
00
Set the data.
4
6
01
00
Set the data, and press PAUSE
button.
5
0
01
00
Set the data.
16. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03RA
Type B: ENC03RB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
2680 to 5080
Note1: Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Note2: The data of page: 0, address: 10 must be “00”.
Switch setting:
1)
STEADY SHOT (CAMERA SET menu) ......................... ON
2)
ZOOM .................................................................... TELE end
Adjusting method:
Order Page Address Data
Procedure
Pitch sensor check
(FB-223 board SE8002)
1
0
03
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
Yaw sensor check
(FB-223 board SE8001)
3
0
03
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note3)
5
0
03
00
Set the data.
6
Move the camcorder, and check
that the steady shot operations
have been performed normally
Note3: Don’t move the camcorder.
Page of 61
Display

Click on the first or last page to see other DCR-PC53E / DCR-PC55 / DCR-PC55E (serv.man4) service manuals if exist.