5-27
14. Mechanical Shutter Adjustment
(DCR-PC5/PC5E)
Adjust the period which the mechanical shutter is closed, and
compensate the exposure.
Adjustment Page
F
7
Adjustment Address
70 to 84
23 to 26
Input method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Input the following data to page: F, addresses: 70 to 84.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
Address
70
71
72
73
74
75
76
77
78
79
7A
7B
7C
7D
7E
7F
80
81
82
83
84
Data
C4
0E
75
0C
26
0B
35
0A
6E
09
A5
61
A1
79
64
81
82
84
B5
7B
20
Address
23
24
25
26
Data
7C
7F
7C
7B
15. Steady Shot Check
Precautions on the Parts Replacement
There are two types of repair parts.
Type A: ENC03LA
Type B: ENC03LB
Replace the broken sensor with a same type sensor. If replace with
other type parts, the image will vibrate up and down or left and
right during hand-shake correction operations. After replacing,
perform the following procedure.
Precautions on Angular Velocity Sensor
The sensor incorporates a precision oscillator. Handle it with care
as if it dropped, the balance of the oscillator will be disrupted and
operations will not be performed properly.
Subject
Arbitrary
Measurement Point
Display data of page 1 (Note1)
Measuring Instrument
Adjustment remote commander
Specified Value
1A00 to 2600
Note1:
Displayed data of the adjustment remote commander.
1 : XX : XX
Display data
Switch setting:
1)
STEADY SHOT (Menu display) ...................................... ON
2)
ZOOM .................................................................... TELE end
Check method:
Order Page Address Data
Procedure
Pitch sensor check
(CF-75 board SE3450)
1
6
04
11
Set the data.
2
1
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Yaw sensor check
(CF-75 board SE3451)
3
6
04
12
Set the data.
4
1
Check that the display data
(Note1) satisfies the specified
value. (Note2)
Steady shot check
5
0
01
01
Set the data.
6
F
10
E2
Set the data, and press PAUSE
button.
7
1
Move the camcoder, and check
that the display data (Note1) is
changing.
8
F
10
E3
Set the data, and press PAUSE
button.
9
1
Move the camcoder, and check
that the display data (Note1) is
changing.
Note2:
Don’t move the camcoder during data check.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
F
10
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
6
04
00
Set the data.
4
Move the camcoder, and check
that the steady shot operations
have been performed normally
3)
Input the following data to page: 7, addresses: 23 to 26.
Note:
Press the PAUSE button of the adjustment remote commander
each time to set the data.
4)
Select page: 0, address: 01, and set data: 00.