DCR-PC330, DCR-PC330E (serv.man8) - Sony Movie Service Manual (repair manual). Page 2

Read Sony DCR-PC330 / DCR-PC330E (serv.man8) Service Manual online

— 2 —
DCR-PC330/PC330E
Sony EMCS Co.
2003K1600-1
  ©2003.11
Published by DI CS Strategy Div.
9-876-272-94
 : Changed portion.
6-1. CAMERA SECTION ADJUSTMENT
1-3.
CAMERA SYSTEM ADJUSTMENTS
15. Auto White Balance Standard Data Input
Adjusting method:
Order Page Address Data
Procedure
6
6
01
42
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note3: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
17. Auto White Balance Adjustment
Adjusting method:
Order Page Address Data
Procedure
12
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
32 to 35, 44 to 47 and to page: 14, address: F4 to FF
24. AF Laser Output Adjustment
Adjusting method:
Order Page Address Data
Procedure
6
6
02
Check that the data is “01”.
(Note5)
10
F
6B
Check that the data is D
75
 
±
 20%.
Note5: The adjustment data will be automatically input to page: F, address:
66 to 6C.
6-3. VIDEO SECTION ADJUSTMENT
3-3.
SERVO AND RF SYSTEM ADJUSTMENT
Before perform the servo and RF system adjustments, check that
the specified value of “54MHz (PC330)/67.5MHz (PC330E) Origin
Oscillation Adjustment” of “CAMERA SYSTEM ADJUSTMENT”
is satisfied.
3-4.
VIDEO SYSTEM ADJUSTMENTS
Note1: Before perform the servo and RF system adjustments, check that
the specified value of “54MHz (PC330)/67.5MHz (PC330E)
Origin Oscillation Adjustment” of “CAMERA SYSTEM
ADJUSTMENT” is satisfied.
INCORRECT
Page 6-34
CORRECT
Adjusting method:
Order Page Address Data
Procedure
6
6
01
41
Set the data, and press PAUSE
button.
7
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
2E to 31 and to page: 14, address: E8 to F3
Adjusting method:
Order Page Address Data
Procedure
12
6
02
Check that the data changes to
“01”. (Note5)
Note5: The adjustment data will be automatically input to page: F, address:
32 to 35, 44 to 47 and to page: 14, address: F4 to FF
Adjusting method:
Order Page Address Data
Procedure
6
6
02
Check that the data is “01”.
(Note6)
10
F
6B
Check that the data is “C0” to “FF”.
Note6: The adjustment data will be automatically input to page: F, address:
66 to 6C.
Before perform the servo and RF system adjustments, check that
the specified value of “54MHz (PC330E)/67.5MHz (PC330) Origin
Oscillation Adjustment” of “CAMERA SYSTEM ADJUSTMENT”
is satisfied.
Note1: Before perform the servo and RF system adjustments, check that
the specified value of “54MHz (PC330E)/67.5MHz (PC330)
Origin Oscillation Adjustment” of “CAMERA SYSTEM
ADJUSTMENT” is satisfied.
Page 6-36
Page 6-42
Page 6-59
Page 6-57
Page of 2
Display

Download Sony DCR-PC330 / DCR-PC330E (serv.man8) Service Manual (Repair Manual)