DCR-PC1000, DCR-PC1000E (serv.man4) - Sony Movie Service Manual (repair manual). Page 8

Read Sony DCR-PC1000 / DCR-PC1000E (serv.man4) Service Manual online

6-5
DCR-PC1000/PC1000E
1-1-2.
Preparations
Note1: For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note2: When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3: Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1)
Connect the equipment for adjustments according to Fig. 6-1-3.
Note4: As removing the front assembly (removing the VC-398 board
CN1001) means removing the lithium 3V power supply (FP-165
flexible, BT001), data such as date, time, user-set menus will be
lost. After completing adjustments, reset these data.
But, the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the front assembly
has been removed. (Refer to “6-4.Service Mode” for the data on
the history use and the self-diagnosis data.)
Note5: Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned
on with the control switch block (PS11800) removed. After
completing adjustments, be sure to exit the “Forced Camera Power
ON Mode”.
Note6: Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: A, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
Fig. 6-1-2.
Pattern box
1.5 m
Front of the lens
0.4 m (PTB-1450)
1.0 m (PTB-450)
Page of 79
Display