DCR-IP5, DCR-IP5E, DCR-IP7BT, DCR-IP7E (serv.man3) - Sony Movie Service Manual (repair manual). Page 10

Read Sony DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) Service Manual online

5-8
DCR-IP5/IP5E/IP7BT/IP7E
1-2.
INITIALIZATION OF B, C, D, E, F, 4, 7, 8, 9
PAGE DATA
1-2-1.
INITIALIZATION OF D, E, F, 7 PAGE DATA
1. Initializing the D, E, F, 7 Page Data
Note1: If “Initializing the D, E, F, 7 Page Data” is performed, all
data of the D page, E page, F page and 7 page will be
initialized. (It is impossible to initialize a single page.)
Note2:
If the D, E, F, 7 page data has been initialized, the following
adjustments need to be performed again.
1) Modification of D, E, F, 7 page data
2) Camera system adjustments
Note3:
NTSC model: DCR-IP5/IP7BT
PAL model: DCR-IP5E/IP7E
Switch setting:
POWER .................................................................. CAMERA
Adjusting page
D
Adjusting Address
10 to FF
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Adjusting page
7
Adjusting Address
00 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
2
00
Set the following data.
2F (NTSC), 37 (PAL)
3
2
01
Set the following data, and press
the PAUSE button.
2F (NTSC), 37 (PAL)
4
2
02
Check that the data changes  from
“00” to “01”
5
Perform “Modification of D, E,
F, 7 Page Data”.
2. Modification of D, E, F, 7 Page Data
If the D, E, F, 7 page data has been initialized, change the data of
the “Fixed data-2” address shown in the following tables by manual
input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of D, E, F, 7 Page
data
Order Page Address Data
Procedure
1
2
00
29
Set the data
2
2
01
29
Set the data, and press the PAUSE
button.
Note:
If the following symptoms occur after completing of the
“Modification of D, E, F, 7 page data”, check that the data of the
“Fixed data-2” addresses of D page are same as those of the same
model of the same destination.
1) The battery end mark on the LCD or viewfinder screen is flashing.
2) The power is shut off so that unit cannot operate.
3. D Page Table
Note:
Fixed data-1: Initialized data. (Refer to “1. Initializing the D, E, F, 7
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of D, E, F, 7
Page Data”.)
Table. 5-1-2.
00 to 0F
10
11
12
13 to 20
21
22 to 26
27
28
29 to 2C
2D
2E
2F
30
31
32
33 to 38
39
3A to 3B
3C
3D to FF
00
Test mode
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
00
Address
Remark
Initial value
NTSC PAL
Page of 63
Display

Click on the first or last page to see other DCR-IP5 / DCR-IP5E / DCR-IP7BT / DCR-IP7E (serv.man3) service manuals if exist.