Read Sony DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) Service Manual online
5-30
DCR-IP45/IP45E/IP55/IP55E
15. Strobe Light Level Adjustment
Adjust the light level when the strobe light flashes.
Adjust the light level when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens) (Note1)
(50cm from the front of the lens) (Note1)
Measurement Point
Adjustment remote commander
Measuring Instrument
Adjustment Page
F
Adjustment Address
8C to 91
Specified Value
Data of page: 6, address: B8 is “00”.
Note1: Background paper (J-250-130-A). Perform this adjustment in the
dark room or use a dark box.
Note2: Any light other than the strobe light should not light up the paper.
Note3: This adjustment should be carried out upon completion of “HALL
Note3: This adjustment should be carried out upon completion of “HALL
Adjustment” , “Flange Back Adjustment”.
Note4: The data of page: 0, address: 10 must be “00”.
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
05
04
Set the data. (Note6)
3
6
01
67
Set the data, and press PAUSE
button.
button.
4
Check the flashing.
5
6
02
Check that the data is “01”.
(Note7)
(Note7)
6
6
B8
Check that the data is “00”.
Note6: Use the STOP button of the adjustment remote commander.
Note7: The adjustment data will be automatically input to page: F, address:
Note7: The adjustment data will be automatically input to page: F, address:
8C to 91.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
7
05
00
Set the data.
3
0
01
00
Set the data.
16. Strobe White Balance Adjustment & Check
Adjust and check the white balance when the strobe light flashes.
Adjust and check the white balance when the strobe light flashes.
Subject
Paper which reflection rate is 18%
(50cm from the front of the lens)
(Note1)
(50cm from the front of the lens)
(Note1)
Measurement Point
Video output terminal
Measuring Instrument
Vectorscope
Adjustment Page
F
Adjustment Address
3E, 3F
Specified Value
Fig. 5-1-13.
Note1: Background paper (J-250-130-A). Perform this adjustment in the
dark room or use a dark box.
Note2: Any light other than the strobe light should not light up the paper.
Note3: This adjustment should be carried out upon completion of “HALL
Note3: This adjustment should be carried out upon completion of “HALL
Adjustment”, “Flange Back Adjustment”, “Auto White Balance
& LV Standard Data Input”, “Auto White Balance Adjustment”,
“Strobe Light Level Adjustment”
& LV Standard Data Input”, “Auto White Balance Adjustment”,
“Strobe Light Level Adjustment”
Note4: The data of page: 0, address: 10 must be “00”.
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page:
Note5: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
1)
POWER .................................................................. CAMERA
2)
FLASH ......................................................................... OPEN
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
(Press FLASH ( ) button and set to the forced flash mode ( ),
and press PHOTO button.)
3)
NIGHT SHOT .................................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
05
04
Set the data. (Note6)
3
6
01
B9
Set the data, and press PAUSE
button.
button.
4
Check the flashing.
5
6
02
Check that the data is “01”.
(Note7)
(Note7)
6
6
02
00
Set the data.
7
6
01
E7
Set the data, and press PAUSE
button.
button.
8
Check the flashing.
9
6
02
Check that the data is “01”.
10
Wait for 3 sec.
11
Check that the center of the
white luminance point is within
the circle shown Fig. 5-1-13.
white luminance point is within
the circle shown Fig. 5-1-13.
Note6: Use the STOP button of the adjustment remote commander.
Note7: The adjustment data will be automatically input to page: F, address:
Note7: The adjustment data will be automatically input to page: F, address:
3E, 3F.
Processing after Completing Adjustments:
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
button.
2
7
05
00
Set the data.
3
0
01
00
Set the data.
Fig. 5-1-13.
R-Y
2mm
B-Y
2mm
Click on the first or last page to see other DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) service manuals if exist.