Read Sony DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) Service Manual online
5-39
DCR-IP45/IP45E/IP55/IP55E
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
7D
7B
Set the data, and press PAUSE button.
3
3
00
05
Set the data, and press PAUSE button.
4
3
02
0F
Set the data.
5
Check that the EVF screen turned
white.
white.
6
4
11
81
Set the data, and press PAUSE button.
7
C
7D
Read the data, and this data is
named PRESET DATA.
named PRESET DATA.
8
C
7D
Add 30 (Hexadecimal) to the data
and press PAUSE button.
and press PAUSE button.
9
C
7D
Check the EVF screen.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
10
Using Table 5-1-14., read the new
PRESET DATA corresponding to
the PRESET DATA.
PRESET DATA corresponding to
the PRESET DATA.
11
C
7D
Set the new PRESET DATA and
press PAUSE button.
press PAUSE button.
12
Return to step 7.
13
C
7D
Set the PRESET DATA and press
PAUSE button.
PAUSE button.
14
C
7D
Subtract 30 (Hexadecimal) from
the data and press PAUSE button.
the data and press PAUSE button.
15
C
7D
Check the EVF screen.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
16
Using Table 5-1-15., read the new
PRESET DATA corresponding to
the PRESET DATA.
PRESET DATA corresponding to
the PRESET DATA.
17
C
7D
Set the new PRESET DATA and
press PAUSE button.
press PAUSE button.
18
Return to step 7.
19
C
7D
Set the PRESET DATA and press
PAUSE button.
PAUSE button.
20
C
7D
Read the data, and this data is
named D
named D
7D
.
21
Convert D
7D
to decimal notation,
and obtain D
7D
’. (Note4)
22
Calculate D
83
’ using following
equations (Decimal calculation)
D
D
83
’=D
7D
’+23
23
Convert D
83
’ to a hexadecimal
number, and obtain D
83
(Note4)
24
C
83
D
83
Set the data, and press PAUSE button.
25
4
11
83
Set the data, and press PAUSE button.
26
3
00
00
Set the data, and press PAUSE button.
27
3
02
00
Set the data.
28
0
01
00
Set the data.
Note4: Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
83
92
Set the data, and press PAUSE button.
3
3
00
05
Set the data, and press PAUSE button.
4
3
02
0F
Set the data.
5
Check that the EVF screen turned
white.
white.
6
4
11
81
Set the data, and press PAUSE button.
7
C
83
Read the data, and this data is
named PRESET DATA.
named PRESET DATA.
8
C
83
Add 30 (Hexadecimal) to the data
and press PAUSE button.
and press PAUSE button.
9
C
83
Check the EVF screen.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
10
Using Table 5-1-16., read the new
PRESET DATA corresponding to
the PRESET DATA.
PRESET DATA corresponding to
the PRESET DATA.
11
C
83
Set the new PRESET DATA and
press PAUSE button.
press PAUSE button.
12
Return to step 7.
13
C
83
Set the PRESET DATA and press
PAUSE button.
PAUSE button.
14
C
83
Subtract 30 (Hexadecimal) from
the data and press PAUSE button.
the data and press PAUSE button.
15
C
83
Check the EVF screen.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
16
Using Table 5-1-17., read the new
PRESET DATA corresponding to
the PRESET DATA.
PRESET DATA corresponding to
the PRESET DATA.
17
C
83
Set the new PRESET DATA and
press PAUSE button.
press PAUSE button.
18
Return to step 7.
19
C
83
Set the PRESET DATA and press
PAUSE button.
PAUSE button.
20
C
83
Read the data, and this data is
named D
named D
83
.
21
Convert D
83
to decimal notation,
and obtain D
83
’. (Note4)
22
Calculate D
7D
’ using following
equations (Decimal calculation)
D
D
7D
’=D
83
’–23
23
Convert D
7D
’ to a hexadecimal
number, and obtain D
7D
(Note4)
24
C
7D
D
7D
Set the data, and press PAUSE button.
25
4
11
83
Set the data, and press PAUSE button.
26
3
00
00
Set the data, and press PAUSE button.
27
3
02
00
Set the data.
28
0
01
00
Set the data.