DCR-IP45, DCR-IP45E, DCR-IP55, DCR-IP55E (serv.man2) - Sony Movie Service Manual (repair manual). Page 105

Read Sony DCR-IP45 / DCR-IP45E / DCR-IP55 / DCR-IP55E (serv.man2) Service Manual online

5-39
DCR-IP45/IP45E/IP55/IP55E
Adjusting method for NTSC model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
7D
7B
Set the data, and press PAUSE button.
3
3
00
05
Set the data, and press PAUSE button.
4
3
02
0F
Set the data.
5
Check that the EVF screen turned
white.
6
4
11
81
Set the data, and press PAUSE button.
7
C
7D
Read the data, and this data is
named PRESET DATA.
8
C
7D
Add 30 (Hexadecimal) to the data
and press PAUSE button.
9
C
7D
Check the EVF screen.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
10
Using Table 5-1-14., read the new
PRESET DATA corresponding to
the PRESET DATA.
11
C
7D
Set the new PRESET DATA and
press PAUSE button.
12
Return to step 7.
13
C
7D
Set the PRESET DATA and press
PAUSE button.
14
C
7D
Subtract 30 (Hexadecimal) from
the data and press PAUSE button.
15
C
7D
Check the EVF screen.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
16
Using Table 5-1-15., read the new
PRESET DATA corresponding to
the PRESET DATA.
17
C
7D
Set the new PRESET DATA and
press PAUSE button.
18
Return to step 7.
19
C
7D
Set the PRESET DATA and press
PAUSE button.
20
C
7D
Read the data, and this data is
named D
7D
.
21
Convert D
7D
 to decimal notation,
and obtain D
7D
’. (Note4)
22
Calculate D
83
’ using following
equations (Decimal calculation)
   D
83
’=D
7D
’+23
23
Convert D
83
’ to a hexadecimal
number, and obtain D
83
 (Note4)
24
C
83
D
83
Set the data, and press PAUSE button.
25
4
11
83
Set the data, and press PAUSE button.
26
3
00
00
Set the data, and press PAUSE button.
27
3
02
00
Set the data.
28
0
01
00
Set the data.
Note4: Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
Adjusting method for PAL model:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
83
92
Set the data, and press PAUSE button.
3
3
00
05
Set the data, and press PAUSE button.
4
3
02
0F
Set the data.
5
Check that the EVF screen turned
white.
6
4
11
81
Set the data, and press PAUSE button.
7
C
83
Read the data, and this data is
named PRESET DATA.
8
C
83
Add 30 (Hexadecimal) to the data
and press PAUSE button.
9
C
83
Check the EVF screen.
When the screen is stable,
proceed to step 13.
When the screen is unstable,
proceed to step 10.
10
Using Table 5-1-16., read the new
PRESET DATA corresponding to
the PRESET DATA.
11
C
83
Set the new PRESET DATA and
press PAUSE button.
12
Return to step 7.
13
C
83
Set the PRESET DATA and press
PAUSE button.
14
C
83
Subtract 30 (Hexadecimal) from
the data and press PAUSE button.
15
C
83
Check the EVF screen.
When the screen is stable,
proceed to step 19.
When the screen is unstable,
proceed to step 16.
16
Using Table 5-1-17., read the new
PRESET DATA corresponding to
the PRESET DATA.
17
C
83
Set the new PRESET DATA and
press PAUSE button.
18
Return to step 7.
19
C
83
Set the PRESET DATA and press
PAUSE button.
20
C
83
Read the data, and this data is
named D
83
.
21
Convert D
83
 to decimal notation,
and obtain D
83
’. (Note4)
22
Calculate D
7D
’ using following
equations (Decimal calculation)
   D
7D
’=D
83
’–23
23
Convert D
7D
’ to a hexadecimal
number, and obtain D
7D
 (Note4)
24
C
7D
D
7D
Set the data, and press PAUSE button.
25
4
11
83
Set the data, and press PAUSE button.
26
3
00
00
Set the data, and press PAUSE button.
27
3
02
00
Set the data.
28
0
01
00
Set the data.
Page of 127