DCR-IP210, DCR-IP210E, DCR-IP220, DCR-IP220E (serv.man4) - Sony Movie Service Manual (repair manual). Page 70

Read Sony DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) Service Manual online

6-67
DCR-IP210/IP210E/IP220/IP220E
4-3.
SERVICE MODE
Note:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1. Setting the Test Mode
Page D
Address 10
Data
00
01
02
03
05
Function
Normal
Forced camera power ON
Forced VTR power ON
Forced camera + VTR power ON
Forced memory power ON
• Before setting the data, select page: 0, address: 01, and set data:
01.
• For page D and F, the data set is recorded in the non-volatile
memory by pressing the PAUSE button of the adjustment remote
commander. In this case, take note that the test mode will not be
exited even when the main power is turned off.
• After completing adjustments/repairs, be sure to return the data
of this address to 00, and press the PAUSE button of the adjustment
remote commander. And select page: 0, address: 01, and set data:
00.
2. Emergence Memory Address
Page C
Address 20 to 2B
Address
20
22
23
24
26
27
28
2A
2B
When no error occurs in this unit, data “00” is written in the above
addresses (20 to 2B). When first error occurs in the unit, the data
corresponding to the error is written in the first emergency address
(20 to 23). In the same way, when the second error occurs, the data
corresponding to the error is written in the second emergency address
(24 to 27).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (28 to 2B).
Note:
After completing adjustments, be sure to initialize the data of
addresses 20 to 2B to “00”.
Contents
EMG code when first error occurs
Upper: MSW code when shift starts when first
error occurs
Lower: MSW code when first error occurs
Lower: MSW code to be moved when first error
occurs
EMG code when second error occurs
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
Lower: MSW code to be moved when second error
occurs
EMG code when last error occurs
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
Lower: MSW code to be moved when last error
occurs
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
3
F6
01
Set the data and press PAUSE
button.
3
3
F6
Check that the data changes to
“00”.
4
0
01
00
Set the data.
2-1. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in
addresses 20, 24 and 28. The type of error indicated by the code are
shown in the following table.
Code
00
10
11
20
21
22
23
31
32
40
41
42
43
Emergency Type
No error
Loading motor emergency during loading
Loading motor emergency during unloading
T reel emergency during unloading
S reel emergency during unloading
T reel emergency during normal rotation
S reel emergency during normal rotation
FG emergency of the capstan
Emergency during reverse rotation of the capstan
FG emergency at the start up of the drum
PG emergency at the start up of the drum
FG emergency during normal rotation of the drum
PG emergency during normal rotation of the drum
COVER
COVER
Page of 76
Display

Click on the first or last page to see other DCR-IP210 / DCR-IP210E / DCR-IP220 / DCR-IP220E (serv.man4) service manuals if exist.