Read Sony DCR-HC94E / DCR-HC96 / DCR-HC96E (serv.man10) Service Manual online
ADJ
SERVICE MANUAL
SUPPLEMENT-2
File this supplement with the service manual.
(DI07-024)
Sony EMCS Co.
2007E0500-1
© 2007.5
Published by Kohda TEC
9-876-932-87
: Points changed portion.
6-1. CAMERA SECTION ADJUSTMENTS
1-2.
INITIALIZATION OF 8, A, B, C, D, E, F, 14, 18,
19, 1A, 1B, 1C, 1E, 1F PAGE DATA
19, 1A, 1B, 1C, 1E, 1F PAGE DATA
1-2-1.
Initialization of A, B, D, 1A, 1B Page Data
5.
D Page table
(Service manual page 6-11)
Former Type
Address
Initial value
Remark
NTSC PAL
31 to 33
Fixed data-1 (Initialized data)
34
Fixed data-2
35 to 48
Fixed data-1 (Initialized data)
49
Fixed data-2
4A, 4B
Fixed data-1 (Initialized data)
4C
Fixed data-2
New Type
Address
Initial value
Remark
NTSC PAL
31, 32
Fixed data-1 (Initialized data)
33
34
Fixed data-2
35 to 48
Fixed data-1 (Initialized data)
49
4A
Fixed data-2
4B
Fixed data-1 (Initialized data)
4C
Fixed data-2
DCR-HC94E/HC96/HC96E
RMT-831
DCR-HC94E/HC96/HC96E_ADJ
Ver. 1.2 2007.05
• Change of 8, D, F and 1F Page table
This SUPPLEMENT-2 is the revised version
of SUPPLEMENT-1.
Replace the SUPPLEMENT-1 (9-876-932-86)
with the SUPPLEMENT-2.
Please discard the SUPPLEMENT-1.
of SUPPLEMENT-1.
Replace the SUPPLEMENT-1 (9-876-932-86)
with the SUPPLEMENT-2.
Please discard the SUPPLEMENT-1.
— 2 —
DCR-HC94E/HC96/HC96E_ADJ
&
: Points added portion.
: Points changed portion.
: Points changed portion.
1-2-2.
Initialization of 8, C, 18, 1C Page Data
3.
8 Page table
(Service manual page 6-13)
Former Type
Address
Initial value
Remark
NTSC PAL
8E
Fixed data-2
8F to BE
Fixed data-1 (Initialized data)
BF
Fixed data-2
New Type
Address
Initial value
Remark
NTSC PAL
8E
Fixed data-2
8F to 93
Fixed data-1 (Initialized data)
94
Fixed data-2
95 to BE
Fixed data-1 (Initialized data)
BF
Fixed data-2
1-2-3.
Initialization of E, F, 14, 19, 1E, 1F Page Data
4.
F Page table
(Service manual page 6-18)
Former Type
Address
Initial value
Remark
NTSC PAL
72
73
Fixed data-2
74 , 75
Fixed data-1 (Initialized data)
New Type
Address
Initial value
Remark
NTSC PAL
72
73
Fixed data-2 (Note)
74 , 75
Fixed data-1 (Initialized data)
8.
1F Page table
(Service manual page 6-21)
Former Type
Address
Initial value
Remark
NTSC PAL
00 to 6F
Fixed data-1 (Initialized data)
70
71
Fixed data-2
New Type
Address
Initial value
Remark
NTSC PAL
00 to 0C
Fixed data-1 (Initialized data)
SI-054 Board (Suffix-11):
0D
Fixed data-1 (Initialized data)
SI-054 Board (Suffix-12):
0E
Fixed data-2
(Note)
0F to 6F
Fixed data-1 (Initialized data)
70
71
Fixed data-2
Note: The data must be changed according to the suffix of the SI-
054 Board, and accordingly refer to the Service Manual
LEVEL 2, Supplement-2 (9-876-932-84).
LEVEL 2, Supplement-2 (9-876-932-84).
)
Note: The data must be changed according to the suffix of the SI-
054 Board, and accordingly refer to the Service Manual
LEVEL 2, Supplement-2 (9-876-932-84).
LEVEL 2, Supplement-2 (9-876-932-84).
)
Display