DCR-HC85, DCR-HC85E (serv.man2) - Sony Movie Service Manual (repair manual). Page 7

Read Sony DCR-HC85 / DCR-HC85E (serv.man2) Service Manual online

1-3
DCR-HC85/HC85E
5.
DISCHARGING OF THE FLASHLIGHT POWER SUPPLY CAPACITOR
The capacitor (ST-076 board C4208) of the flash unit is charged up to the maximum 300V potential. There is a danger of electric shock by
this high voltage when the ST-076 board is handled by hand. The electric shock is caused by the charged voltage which is kept without
discharging when the main power of the unit is simply turned off. Therefore, the remaining voltage must be discharged as described below.
5-1.
PREPARING THE SHORT JIG
To preparing the short jig. a small clip is attached to each end of a resistor of 1k
/1W (1-215-869-11). Wrap insulating tape fully around the
reads of the resistor to prevent electric shock.
5-2.
DISCHARGING THE  CAPACITOR
1
Open the flash.
2
Remove the cabinet (F) section.
3
Remove the cabinet (R) section.
4
Remove the EVF section.
5
Remove the VC-360 board.
6
Remove the mechanism deck.
7
Short-circuit between TP0901 and GND of the ST-103 board  with the short jig about 10 seconds.
1 k
 
/1 W
Wrap insulating tape
Short jig (
1k
/1W
)
Hole of GND
Power supply capacitor
Hole of TP0901
Page of 67
Display