DCR-HC39E, DCR-HC41, DCR-HC42, DCR-HC42E, DCR-HC43, DCR-HC43E (serv.man4) - Sony Movie Service Manual (repair manual). Page 58

Read Sony DCR-HC39E / DCR-HC41 / DCR-HC42 / DCR-HC42E / DCR-HC43 / DCR-HC43E (serv.man4) Service Manual online

6-55
DCR-HC39E/HC41/HC42/HC42E/HC43/HC43E
3-5.
AUDIO SYSTEM ADJUSTMENTS
(DCR-HC39E)
[Connecting the measuring instruments for the audio]
Connect the audio system measuring instruments in addition to
the video system measuring instruments as shown in Fig. 6-3-9.
Fig. 6-3-9
Audio
Video
oscillator
Pattern generator
Video output
(75 
)
Attenuator
600 
600 
 (270 
 (1-249-410-11) +330 
 (1-249-411-11))
Main unit
Main unit
47 k 
47 k 
: 1-249-437-11
Audio level meter or
distortion meter
TV monitor
A/V OUT
 jack
A/V OUT
jack
L
R
Video
Audio (L)
Audio (R)
In Recording (PLAY/EDIT mode)
In Playback (PLAY/EDIT mode)
1.
Playback Level Check
Mode
Playback (PLAY/EDIT mode)
Signal
Alignment tape:
For audio operation check
(XH5-3P)
Measurement Point
Audio left or right terminal of A/V
jack
Measuring Instrument
Audio level meter and frequency
counter
Specified Value
32 kHz mode: 1 kHz, + 3.0 
±
 2.0 dBs
48 kHz mode: 1 kHz, + 3.0 
±
 2.0 dBs
44.1 kHz mode:
The 7.35 kHz signal level during EMP
OFF is +2.0 
±
 2.0 dBs.
The 7.35 kHz signal level during EMP
ON is 
±
 2 dB from the signal level
during EMP OFF.
Checking Method:
1) Check that the playback signal level is the specified value.
2. Overall Level Characteristics Check
Mode
Recording and playback (PLAY/
EDIT mode)
Signal
400 Hz, 
7.5 dBs signal:
Audio left and right terminal of A/V
OUT jack
Measurement Point
Audio left or right terminal of A/V
OUT jack
Measuring Instrument
Audio level meter
Specified Value
–7.5 
±
 3.0 dBs
Checking Method:
1) Select page: 7, address: 01, and set data: 94.
2) Select page: 7, address: 04, and set data: 0E.
3) Select page: 7, address: 00, set data: 01, and press the PAUSE
button.
4) Select page: 7, address: 02, and check that the changes to “01”.
5) Input the 400 Hz, –7.5 dBs signal in the audio left and right
terminal of A/V OUT jack.
6) Record the signal.
7) Remove the input signal.
8) Playback the recorded section.
9) Check that the 400 Hz signal level is the specified value.
10) Select page: 7, address: 01, and set data: 94.
11) Select page: 7, address: 04, and set data: 0F
12) Select page: 7, address: 00, set data: 01, and press the PAUSE
button.
13) Select page: 7, address: 02, and check that the changes to “01”.
Page of 72