6-50
DCR-HC23E/HC24E/HC26/HC26E/HC35E_ADJ
2-3. Emergence Memory Address (Mechanism
section)
Page C
Address F4 to FF
Address
Contents
F4
EMG code when first error occurs
F6
Upper: MSW code when shift starts when first error
occurs
Lower: MSW code when first error occurs
F7
Lower: MSW code to be moved when first error
occurs
F8
EMG code when second error occurs
FA
Upper: MSW code when shift starts when second
error occurs
Lower: MSW code when second error occurs
FB
Lower: MSW code to be moved when second error
occurs
FC
EMG code when last error occurs
FE
Upper: MSW code when shift starts when last error
occurs
Lower: MSW code when last error occurs
FF
Lower: MSW code to be moved when last error
occurs
When no error occurs in this unit, data “00” is written in the above
addresses (F4 to FF). when first error occurs in the unit, the data
corresponding to the error is written in the first emergency ad-
dress (F4 to F7). In the same way, when the second error occurs,
the data corresponding to the error is written in the second emer-
gency address (F8 to FB).
Finally, when the last error occurs, the data corresponding to the
error is written in the last emergency address (FC to FF).
Note: After completing adjustments, be sure to initialize the data
of addresses F4 to FF to “00”.
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
3
03
FF
Press PAUSE (Write) button.
3
3
01
37
Press PAUSE (Write) button.
4
3
02
Check the data changes to
“00”.
5
3
03
Check the data changes to
“00”.
6
0
01
00
2-4. EMG Code (Emergency Code)
Codes corresponding to the errors which occur are written in C
page, addresses F4, F8 and FC . The type of error indicated by the
code are shown in the following table.
Code
Emergency Type
00
No error
10
Loading motor emergency during loading
11
Loading motor emergency during unloading
22
T reel emergency during normal rotation
23
S reel emergency during normal rotation
24
T reel emergency (Short circuit between S reel
terminal and T reel terminal)
30
FG emergency at the start up of the capstan
40
FG emergency at the start up of the drum
42
FG emergency during normal rotation of the drum
Page of 61