6-18
DCR-HC23E/HC24E/HC26/HC26E/HC35E_ADJ
2.
HALL Adjustment
RadarW
RadarW
RadarW
For detecting the position of lens iris, adjust the hall AMP gain
and offset.
and offset.
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
12 to 18
Specified value
Data of page: 6, address: 0C is “00”
Note 1: Check that the data of page: 0, address: 10 is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
Note 2: Check that the data of page: 6, address: 02 is “00”.
If not, select page: 6, address: 01, set data: 00, and press
the PAUSE (Write) button.
the PAUSE (Write) button.
Switch setting:
1) POWER ......................................................... CAMERA mode
1) POWER ......................................................... CAMERA mode
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
D0
40
3
6
01
6D
Press PAUSE (Write) button.
(Note 3)
(Note 3)
4
6
02
Check the data changes to
“01”.
“01”.
5
6
0C
Check the data is “00”.
Note 3: The adjustment data will be automatically input to page:
F, address: 12 to 18.
Processing after completing adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE (Write) button.
2
0
01
00
1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except “36MHz Origin Oscillation Adjustment”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
specified values of “VIDEO SYSTEM ADJUSTMENTS” are sat-
isfied. (Except “36MHz Origin Oscillation Adjustment”)
Check that the data of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
1.
36MHz Origin Oscillation Adjustment
(VC-416 board)
(VC-416 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Subject
Not required
Measurement Point
Pin qh of IC3002 on VC-416 board
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 18000000
± 90 Hz
Note 1: Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
frequency (f) to the specified
value.
3
F
10
Press PAUSE (Write) button.
4
0
01
00
Fig. 6-1-8
48
1
12
1316
Measurement Point
37
36
24
25
IC3002
VC-416 board (SIDE A)