DCR-HC21 (serv.man2) - Sony Movie Service Manual (repair manual). Page 14

Read Sony DCR-HC21 (serv.man2) Service Manual online

6-11
DCR-HC21
2.
Modification of A, D Page Data
If the A, D page data has been initialized, change the data of
the“Fixed data-2” address shown in the following table by manual
input.
Modifying method:
1) Before changing the data, select page: 0, address: 01, and set
data: 01.
2) New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note 1:
If copy the data built in the different model, the
camcorder may not operate.
3) When changing the data, press the PAUSE button of the ad-
justment remote commander each time when setting new data
to write the data in the non-volatile memory.
4) Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after completing modification A, D page data:
Order Page Address Data
Procedure
1
2
00
29
2
2
01
29
Press PAUSE button.
Note 2:
If the following symptoms occur after completing of
the“Modification A, D page data”, check that the data of
the “Fixed data-2” addresses of A, D page are same as
those of the same model of the same destination.
1) The power is shut off so that unit cannot operate.
1-2-1.
Initialization of A, D Page Data
Note:
 Check that the data of page: 0, address: 10 is “00”.
1.
Initializing of A, D Page Data
Note 1:
If “Initialization of Pages A, D” is executed, all data on
pages A, D are initialized.
Note 2:
If the A, D page data has been initialized, the following
adjustments need to be performed again.
1)  Modification of A, D page data
2)  Touch panel adjustment
Note 3:
NTSC model: DCR-HC21/HC32/HC33
PAL model: DCR-HC17E/HC19E/HC21E/HC22E/
HC32E/HC33E
Adjustment Page
A
Adjustment Address
10 to FF
Adjustment Page
D
Adjustment Address
10 to 7F
Initializing method:
Order Page Address Data
Procedure
1
0
01
01
2
0
10
00
3
7
03
Set the following data.
01: NTSC model
81: PAL model
4
7
00
Set the following data.
20: Initializing A page
22: Initializing D page
28: Initializing A and D pages
5
7
01
Set the following data, and
press PAUSE button.
20: Initializing A page
22: Initializing D page
28: Initializing A and D pages
6
7
02
Check the data changes to
“01”.
7
Perform “Modification of A,
D Page Data”
1-2.
INITIALIZATION OF 8, A, C, D, E, F, 1C, 1F
PAGE DATA (Non MS model)
Note 1:
If reading/writing data on pages 1C, 1F, set data: 01 to
page: 0, address: 10, and then select pages C, F. By this
data setting, the pages 1C, 1F can be selected.
After the data reading/writing finished, return the data
on page: 0, address: 10 to “00”.
Note 2:
Non MS model: DCR-HC17E/HC19E/HC21/HC21E/
HC22E
Page of 89
Display