Read Sony DCR-HC17E / DCR-HC19E / DCR-HC21 / DCR-HC21E / DCR-HC22E / DCR-HC32 / DCR-HC32E / DCR-HC33 / DCR-HC33E (serv.man7) Service Manual online
— 5 —
DCR-HC17E/HC19E/HC21/HC21E/HC22E/HC32/HC32E/HC33/HC33E
5.
Transmissive Mode White Balance Adjustment
(PD-236/237 board)
(PD-236/237 board)
Correct the white balance at transmissive mode.
If deviated, the LCD screen color cannot be reproduced.
If deviated, the LCD screen color cannot be reproduced.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Check on LCD screen
Measuring Instrument
Adjustment Page
C
Adjustment Address
56, 57
Specified Value
LCD screen must not be colored
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check the white balance only when replacing the following
parts. If necessary, adjust them.
parts. If necessary, adjust them.
1. LCD block
2. Light induction plate
3. IC602
2. Light induction plate
3. IC602
Note 3:
Non MS model: DCR-HC17E/HC19E/HC21/HC21E/
HC22E
MS model: DCR-HC32/HC32E/HC33/HC33E
Switch setting:
LCD BACKLIGHT .................................................................. ON
LCD BACKLIGHT .................................................................. ON
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
C
56
Set the following data, and
Press PAUSE button.
Press PAUSE button.
7D: Non MS model
88: MS model
88: MS model
3
C
57
Set the following data, and
Press PAUSE button.
Press PAUSE button.
73: Non MS model
71: MS model
71: MS model
4
Check that the LCD screen is
not colored. If not colored,
proceed to step 6.
not colored. If not colored,
proceed to step 6.
5
C
Change the data so that the
LCD screen is not colored.
(Note 4)
LCD screen is not colored.
(Note 4)
6
0
01
00
Note 4:
To write in the non-volatile memory (EEPROM), press
the PAUSE button each time to set the data.
the PAUSE button each time to set the data.
56
57
57