DCR-HC14E, DCR-HC15, DCR-HC15E (serv.man4) - Sony Movie Service Manual (repair manual). Page 7

Read Sony DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) Service Manual online

6-5
DCR-HC14E/HC15/HC15E
1-1-2.
Preparations
Note1:
For details of how remove the cabinet and boards, refer to “2.
DISASSEMBLY”.
Note2:
When performing only the adjustments, the lens block and boards
need not be disassembled.
Note3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
1)
Connect the equipment for adjustments according to Fig. 6-1-3.
Note4:
As removing the cabinet (R) assembly (removing CN4005 of the
VA-118 board) means removing the lithium 3V power supply
(BT5201 on the CK-129 board), data such as date, time, user-set
menus will be lost. After completing adjustments, reset these data.
But the self-diagnosis data and the data on history of use (total
drum rotation time etc.) will be kept even if the lithium 3V power
supply is removed. (Refer to “6-4.Service Mode” for the self-
diagnosis data and the data on history of use.)
Note5:
Setting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 01, and press the PAUSE
button.
The above procedure will enable the camera power to be turned
on with the control switch block (FK-CX4000) removed. After
completing adjustments, be sure to exit the “Forced Camera Power
ON Mode”.
Note6:
Exiting the “Forced Camera Power ON” Mode
1) Select page: 0, address: 01, and set data: 01.
2) Select page: D, address: 10, set data: 00, and press the PAUSE
button.
3) Select page: 0, address: 01, and set data: 00.
Fig. 6-1-2.
1.5 m
Front of the lens
Pattern box
Page of 62
Display

Click on the first or last page to see other DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) service manuals if exist.