6-31
DCR-HC14E/HC15/HC15E
1-5.
LCD SYSTEM ADJUSTMENT
Note1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note3:
Before performing the adjustments, check the data of page: 0,
address: 10 is “00”. If not, set data: 00 to this address.
Note4:
NTSC model : DCR-HC15
PAL model
: DCR-HC14E/HC15E
Switch setting
LCD panel ...................................................................... Open
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN1004 of the VC-311 board. Connect the
measuring instruments via the multi CPC-7 jig (J-6082-382-A). The
following table shows the Pin No. and signal name of CN1004.
Table 6-1-11.
1. VCO Adjustment (PD-188 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 7 of CN1004 of VC-311 board
(H START)
Measuring Instrument
Frequency counter
Adjustment Page
C
Adjustment Address
47, 48
Specified Value
f = 15734 ± 30Hz (NTSC)
f = 15625 ± 30Hz (PAL)
Note1:
The data of page: 0, address: 10 must be “00”.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
C
47
Change the data and set the VCO
frequency (f) to the specified
value.
3
C
47
Press PAUSE button.
4
C
47
Read the data, and this data is
named D
47
.
5
Convert D
47
 to decimal notation,
and obtain D
47
’. (Note2)
6
Calculate D
48
’ using following
equations (Decimal calculation)
[NTSC model]
When D
47
’   229
D
48
’ = D
47
’ + 26
When D
47
’ > 229
D
48
’ = 255
[PAL model]
When D
47
’   26
D
48
’ = D
47
’ – 26
When D
47
’ < 26
D
48
’ = 0
7
Convert D
48
’ to a hexadecimal
number, and obtain D
48
. (Note2)
8
C
48
D
48
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note2:
Refer to “Table 6-4-1. Hexadecimal-decimal Conversion Table”.
Pin No.
1
2
3
4
5
6
7
8
Signal Name
FRRV
RF MON
RF IN/LANC
JACK IN
SWP
PANEL COM
REG_GND
H START
REG_GND
Pin No.
9
10
11
12
13
14
15
16
Signal Name
PANEL VG
REG_GND
EVF VCO
REG_GND
EVF VG
EXT DA
LANC SIG
N.C.
Fig. 6-1-18.
CN1004
Remove the CPC lid