DCR-HC14E, DCR-HC15, DCR-HC15E (serv.man4) - Sony Movie Service Manual (repair manual). Page 26

Read Sony DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) Service Manual online

6-24
DCR-HC14E/HC15/HC15E
11. Auto White Balance Standard Data Input
Adjust the white balance reference at 3200K.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
1A to 1D
Note1:
This adjustment should be carried out upon completion of “Flange
back adjustment”,  “Optical Axis Adjustment” and “Color
reproduction adjustment”.
Note2:
The data of page: 0, address: 10 must be “00”.
Note3:
Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
POWER ................................................................. CAMERA
2)
NIGHT SHOT .................................................................. OFF
3)
DIGITAL ZOOM (Menu setting) .................................... OFF
4)
STEADY SHOT (Menu setting) ...................................... OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
6
48
02
Set the data.
3
6
01
11
Set the data, and press PAUSE
button.
4
6
01
0B
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”. (Note4)
Note4:
The adjustment data will be automatically input to page: F, address:
1A to 1D.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
6
48
00
Set the data.
3
0
01
00
Set the data.
4
Perform  “Auto White Balance
Adjustment”.
Page of 62
Display

Click on the first or last page to see other DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) service manuals if exist.