DCR-HC14E, DCR-HC15, DCR-HC15E (serv.man4) - Sony Movie Service Manual (repair manual). Page 16

Read Sony DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) Service Manual online

6-14
DCR-HC14E/HC15/HC15E
1-2-3.
INITIALIZATION OF E, F PAGE DATA
Note:
The data of page: 0, address: 10 must be “00”.
1. Initializing the E, F Page Data
Note1:
If “Initializing the E, F Page Data” is performed, all data of the E
page and F page will be initialized. (It is impossible to initialize a
single page.)
Note2:
If the E, F page data has been initialized, following adjustments
need to be performed again.
1) Modification of E, F page data
2) Camera system adjustments
Note3:
The power supply voltage must be 6.0 ± 0.1Vdc.
Note4:
NTSC model : DCR-HC15
PAL model
: DCR-HC14E/HC15E
Adjusting page
E
Adjusting Address
00 to FF
Adjusting page
F
Adjusting Address
10 to FF
Initializing Method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
0
10
00
Set the data.
3
6
01
Set the following data, and press
PAUSE button.
2D (NTSC), 2F (PAL)
4
6
03
FF
Set the data, and press PAUSE
button.
5
6
02
Check that the data changes to
“01”.
6
Perform “Modification of E, F
Page Data”.
2. Modification of E, F Page Data
If the E, F page data has been initialized, change the data of the
“Fixed data-2” address shown in the following table by manual input.
Modifying Method:
1)
Before changing the data, select page: 0, address: 01, and set
data: 01.
2)
New data for changing are not shown in the tables because
they are different in destination. When changing the data, copy
the data built in the same model.
Note:
If copy the data built in the different model, the camcorder may
not operate.
3)
When changing the data, press the PAUSE button of the
adjustment remote commander each time when setting new
data to write the data in the non-volatile memory.
4)
Check that the data of adjustment addresses is the initial value.
If not, change the data to the initial value.
Processing after Completing Modification of E, F Page data
Order Page Address Data
Procedure
1
0
10
00
Set the data.
2
2
00
29
Set the data.
3
2
01
29
Set the data, and press PAUSE
button.
4
Perform “36MHz Origin Osc.
Adjustment” of the camera
system adjustment.
3. E Page Table
Note1:
The data of page: 0, address: 10 must be “00”.
Note2:
Fixed data-1: Initialized data. (Refer to “1. Initializing the E, F
Page Data”.)
Fixed data-2: Modified data. (Refer to “2. Modification of E, F
Page Data”).
Address
Remark
00 to 29
2A
2B to D7
D8
D9
DA to FF
Fixed data-1
Fixed data-2
Fixed data-1
Fixed data-2
Fixed data-1
Table. 6-1-7.
Page of 62
Display

Click on the first or last page to see other DCR-HC14E / DCR-HC15 / DCR-HC15E (serv.man4) service manuals if exist.