1.
Check the area of your repair for unsoldered or poorly-soldered
connections.  Check the entire board surface for solder splashes
and bridges.
2.
Check the interboard wiring to ensure that no wires are
“pinched” or contact high-wattage resistors.
3.
Look for unauthorized replacement parts, particularly
transistors, that were installed during a previous repair.  Point
them out to the customer and recommend their replacement.
4.
Look for parts which, through functioning, show obvious signs
of deterioration.  Point them out to the customer and
recommend their replacement.
5.
Check the B+ voltage to see it is at the values specified.
6.
Flexible Circuit Board Repairing
• Keep the temperature of the soldering iron around 270˚C
during repairing.
• Do not touch the soldering iron on the same conductor of the
circuit board (within 3 times).
• Be careful not to apply force on the conductor when soldering
or unsoldering.
Unleaded solder
Boards requiring use of unleaded solder are printed with the lead-
free mark (LF) indicating the solder contains no lead.
(Caution: Some printed circuit boards may not come printed with
the lead free mark due to their particular size.)
 : LEAD FREE MARK
Unleaded solder has the following characteristics.
• Unleaded solder melts at a temperature about 40
°
C higher than
ordinary solder.
Ordinary soldering irons can be used but the iron tip has to be
applied to the solder joint for a slightly longer time.
Soldering irons using a temperature regulator should be set to
about 350
°
C.
Caution: The printed pattern (copper foil) may peel away if the
heated tip is applied for too long, so be careful!
• Strong viscosity
Unleaded solder is more viscous (sticky, less prone to flow) than
ordinary solder so use caution not to let solder bridges occur such
as on IC pins, etc.
• Usable with ordinary solder
It is best to use only unleaded solder but unleaded solder may
also be added to ordinary solder.
SAFETY CHECK-OUT
After correcting the original service problem, perform the following
safety checks before releasing the set to the customer.
SAFETY-RELATED COMPONENT WARNING!!
COMPONENTS IDENTIFIED BY MARK 
0
 OR DOTTED LINE WITH
MARK 
0
 ON THE SCHEMATIC DIAGRAMS AND IN THE PARTS
LIST ARE CRITICAL TO SAFE OPERATION. REPLACE THESE
COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS
APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS
PUBLISHED BY SONY.
ATTENTION AU COMPOSANT AYANT RAPPORT
À LA SÉCURITÉ!
LES COMPOSANTS IDENTIFÉS PAR UNE MARQUE 
0
 SUR LES
DIAGRAMMES SCHÉMATIQUES ET LA LISTE DES PIÈCES SONT
CRITIQUES POUR LA SÉCURITÉ DE FONCTIONNEMENT. NE
REMPLACER CES COMPOSANTS QUE PAR DES PIÈSES SONY
DONT LES NUMÉROS SONT DONNÉS DANS CE MANUEL OU
DANS LES SUPPÉMENTS PUBLIÉS PAR SONY.
CAUTION
Use of controls or adjustments or performance 
procedures other than those specified herein may 
result in hazardous radiation exposure.
DVD92E
AEP, NE, UK
PAL
DVD103
US, CND, E, AR
NTSC
a
Color
a
a
a
DVD92
US, CND, E, BR
NTSC
Destination
Color System
Remote
Commander
View Finder
USB Terminal
Line REC
Lens Barrier
DVD602
E, KR
NTSC
DVD653
E, JE
NTSC
Table for difference of function
DVD602E
E, AUS
PAL
DVD653E
E, HK, AUS, JE
PAL
W/B
W/B
a
Color
a
a
a
• Abbreviation
CND : Canadian model
HK
: Hong Kong model
AUS : Australian model
NE
: North European model
CAUTION :
Danger of explosion if battery is incorrectly replaced.
Replace only with the same or equivalent type.
KR
: Korea model
JE
: Tourist model
AR
: Argentina model
BR
: Brazilian model
There are two types of the MD board of this model.
One is the MD-114 board and the other is the MD-120 board.
Method of identifying  the two different MD boards is shown on page 3.
WARNING!!
WHEN  SERVICING,  DO  NOT  APPROACH  THE  LASER
EXIT  WITH  THE  EYE  TOO  CLOSELY.  IN  CASE  IT  IS
NECESSARY  TO  CONFIRM  LASER  BEAM  EMISSION,
BE  SURE  TO  OBSERVE  FROM  A  DISTANCE  OF MORE
THAN   30  cm  FROM  THE  SURFACE  OF  THE
OBJECTIVE  LENS  ON  THE  OPTICAL  PICK-UP  BLOCK.
CAUTION:
The use of optical instrument with this product will increase eye
hazard.
Page of 68
Display

Click on the first or last page to see other DCR-DVD92 service manuals if exist.