DCR-DVD505, DCR-DVD505E, DCR-DVD905, DCR-DVD905E (serv.man3) - Sony Movie Service Manual (repair manual). Page 6

Read Sony DCR-DVD505 / DCR-DVD505E / DCR-DVD905 / DCR-DVD905E (serv.man3) Service Manual online

— 6 —
DCR-DVD505/DVD505E/DVD905/DVD905E_L1
3.
Self-diagnosis Code Table
C
C
C
C
C
C
Block
Function
0
4
1
3
1
3
2
1
3
2
3
2
Detailed
Code
0
0
0
0
0
2
0
0
5
0
6
0
Symptom/State
Non-standard battery is used.
Faulty disc is used.
Disc access error
Condensation.
Codec IC dose not return any reply
Difficult to adjust focus
(Cannot initialize focus.)
Self-diagnosis Code
Repaired b
y:
Correction
Use the InfoLITHIUM battery.
Use a compatible disc with the camcorder.
Clean the disc with the supplied cleaning cloth.
Use a compatible disc with the camcorder.
Remove the disc, and insert it again after one hour.
Remove the power source. Reconnect it again and operate your
camcorder again
Retry turn the power on by the power switch.
Page of 8