Read Sony DCR-DVD201 / DCR-DVD201E (serv.man4) Service Manual online
6-40
DCR-DVD201/DVD201E
3. VIDEO OUT Y, Chroma Level Check (VC-354 Board)
Mode
MOVIE (
)
Subject
Arbitrary
Measurement Point
Video terminal of AUDIO VIDEO
jack (75
jack (75
Ω
terminated)
Measuring Instrument
Oscilloscope
Specified Value
Sync level : A = 286 ± 18mV (NTSC)
A = 300 ± 18mV (PAL)
Burst level : B = 286 ± 18mV (NTSC)
B = 300 ± 18mV (PAL)
Note:
The data of page: 0, address: 10 must be “00”.
Switch setting:
DEMO MODE (Menu setting) ........................................ OFF
Adjusting method:
Order Page Address Data
Procedure
1
3
00
00
Set the data.
2
3
0C
03
Set the data, and press PAUSE
button.
button.
3
Check that the sync signal level
(A) satisfies the specified value.
(A) satisfies the specified value.
4
Check that the burst signal level
(B) satisfies the specified value.
(B) satisfies the specified value.
5
3
0C
00
Set the data, and press PAUSE
button.
button.
Fig. 6-2-5.
H
B
A