Read Sony CCD-TRV128 (serv.man2) Service Manual online
CCD-TRV128
6-31
3-4.
VIDEO SYSTEM ADJUSTMENTS
Before perform the video system adjustments, check that the data
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Video system adjustments must be performed in the following or-
der.
of page: 0, address: 10 is “00”.
If not, select page: 0, address: 10, and set the data “00”.
Video system adjustments must be performed in the following or-
der.
Adjusting Procedure:
1. 28 MHz origin oscillation adjustment
2. AFC f
1. 28 MHz origin oscillation adjustment
2. AFC f
0
adjustment
3. S VIDEO OUT Y level adjustment
4. S VIDEO OUT C level adjustment
5. VIDEO OUT level check
6. REC Y current adjustment
7. REC C/AFM current adjustment
4. S VIDEO OUT C level adjustment
5. VIDEO OUT level check
6. REC Y current adjustment
7. REC C/AFM current adjustment
1. 28 MHz Origin Oscillation Adjustment
(VC-341 board)
Set the frequency of the clock for synchronization.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
If deviated, the synchronization will be disrupted and the color
will become inconsistent.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Pin qa of IC151
Measuring Instrument
Frequency counter
Adjustment Page
F
Adjustment Address
10
Specified value
f = 14318181
± 68 Hz (NTSC model)
f = 14187500
± 54 Hz (PAL model)
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Refer to “2. DISASSEMBLY”, when opening the VC-
341 board.
341 board.
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
F
10
Change the data and set the
frequency (f) to the specified
value.
frequency (f) to the specified
value.
3
F
10
Press PAUSE button.
4
0
01
00
Fig. 6-3-4
2. AFC f
0
Adjustment (VC-341 board)
RadarW
RadarW
RadarW
Adjust the pull-in range of A/D converted clock generator during
playback.
playback.
Mode
VTR stop (PLAY/EDIT mode)
Signal
No signal
Measurement Point
Displayed data of page: 3, address: 03
Measuring Instrument
Adjusting remote commander
Adjustment Page
C
Adjustment Address
19
Specified value
The data of page: 3, address: 03 is “00”
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Adjusting method:
Order Page Address Data
Procedure
1
Close the cassette compartment
without inserting cassette.
without inserting cassette.
2
0
01
01
3
3
01
82
Press PAUSE button.
4
3
02
Check the data changes to
“00”.
“00”.
5
3
03
Check that the data is “00”.
(Note 2)
(Note 2)
6
0
01
00
Note 2:
If the data is other than“00”, adjustment has errors.
IC151
13
12 11 1
36
25
24
48
37
Measurement
Point
Point
VC-341 BOARD (SIDE B)
Click on the first or last page to see other CCD-TRV128 (serv.man2) service manuals if exist.