1-3.
CAMERA SYSTEM ADJUSTMENTS
Before perform the camera system adjustments, check that the
specified values of “28 MHz Origin Oscillation Adjustment”, “S
VIDEO OUT Y level Adjustment” and “S VIDEO OUT C level
Adjustment” of “VIDEO SYSTEM ADJUSTMENT” are satisfied.
Check that the data of page: 0, address: 10, is “00”.
If not, select page: 0, address: 10, and set data “00”
1. HALL Adjustment 
RadarW
RadarW
RadarW
For detecting the position of lens iris, adjust the hall AMP gain
and offset.
Mode
CAMERA
Subject
Not required
Measurement Point
Displayed data of page: 1 (Note 3)
Measuring Instrument
Adjusting remote commander
Adjustment Page
F
Adjustment Address
12 to 17
Specified value
87 to 8B during IRIS OPEN
15 to 19 during IRIS CLOSE
Note 1:
Check that the data of page: 0, address: 10 is “00”.
Note 2:
Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 3:
The right two digits of the page: 1 displayed data of the
adjusting remote commander.
1:00:XX
Displayed data
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
2
6
94
89
3
6
95
17
4
6
01
6D
Press PAUSE button. (Note 4)
5
6
02
Check the data changes to
“01”.
6
6
01
00
Press PAUSE button.
Note 4:
The adjustment data will be automatically input to page:
F, address: 12 to 17.
Checking method:
Order Page Address Data
Procedure
1
0
03
03
2
6
01
01
Press PAUSE button.
3
1
Check that the displayed data
(Note 3) during IRIS OPEN
satisfied the specified value.
4
6
01
03
Press PAUSE button.
5
1
Check that the displayed data
(Note 3) during IRIS CLOSE
satisfied the specified value.
Processing after Completing Adjustment:
Order Page Address Data
Procedure
1
6
01
00
Press PAUSE button.
2
6
94
00
3
6
95
00
4
0
03
00
5
0
01
00
Page of 51