CCD-TRV107E, CCD-TRV108E, CCD-TRV208E, CCD-TRV408E - Sony Movie Service Manual (repair manual). Page 123

Read Sony CCD-TRV107E / CCD-TRV108E / CCD-TRV208E / CCD-TRV408E Service Manual online

5-24
CCD-TRV107E/TRV108E/TRV208E/TRV408E
1-5.
LCD SYSTEM ADJUSTMENT
Note 1:
The back light (fluorescent tube) is driven by a high voltage AC
power supply. Therefore, do not touch the back light holder to
avoid electrical shock.
Note 2:
When replacing the LCD unit, be careful to prevent damages
caused by static electricity.
Note 3:
Set the LCD BRIGHT (Menu display) to the center.
Set the LCD COLOR (Menu display) to the center.
Note 4:
Connect the adjustment remote commander to CN713 of VC-272
board via CPC jig for SB (J-6082-539-A). To operate the
adjustment remote commander, connect the AC power adapter
(8.4Vdc) to the DC IN jack of CPC jig for SB, or connect the L
series Info-LITHIUM battery to the battery terminal of CPC jig
for SB.
[Adjusting connector]
Most of the measuring points for adjusting the LCD system are
concentrated in CN5502 of the PD-156 board. Connect the
measuring instruments via the multi CPC jig (J-6082-311-A). The
following table shows the Pin No. and signal name of CN5502.
Table 5-1-8.
1. VCO Adjustment (PD-156 board)
Set the VCO free-run frequency. If deviated, the LCD screen will
be blurred.
Mode
VTR stop
Signal
No signal
Measurement Point
Pin 8 of CN5502 (XHD OUT)
Measuring Instrument
Frequency counter
Adjustment Page
7
Adjustment Address
43, 44
Specified Value
f = 15625 ± 30Hz
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
7
43
Change the data and set the VCO
frequency (f) to the specified
value.
3
7
43
Press PAUSE button.
4
7
43
Read the data, and this data is
named D
43
.
5
Convert D
43
 to decimal notation,
and obtain D
43
’. (Note)
6
Calculate D
44
’ using following
equations (Decimal calculation)
When D
43
’   20
D
44
’ = D
43
’ – 20
When D
43
’ < 20
D
44
’ = 00
7
Convert D
44
’ to a hexadecimal
number, and obtain D
44
. (Note)
8
7
44
D
44
Set the data, and press PAUSE
button.
9
0
01
00
Set the data.
Note:
  Refer to “Table 5-4-1. Hexadecimal-decimal Conversion Table”.
Pin No.
1
3
5
7
9
Signal Name
VB
VG
VR
C-SYNC/XHD
GND
Pin No.
2
4
6
8
10
Signal Name
XVD OUT
PANEL COM
PANEL ID
XHD OUT
GND
PD-156 board
10
9
1
2
CN5502
Page of 127
Display

Click on the first or last page to see other CCD-TRV107E / CCD-TRV108E / CCD-TRV208E / CCD-TRV408E service manuals if exist.