CCD-TRV107, CCD-TRV108, CCD-TRV308, CCD-TRV408, CCD-TRV608 - Sony Movie Service Manual (repair manual). Page 114

Read Sony CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 Service Manual online

5-17
CCD-TRV107/TRV108/TRV308/TRV408/TRV608
7. Auto White Balance & LV Standard Data Input
Adjust the white balance reference at 3200K, and adjust the normal
coefficient of the light value.
Subject
Clear chart
(Color reproduction adjustment frame)
Adjustment Page
F
Adjustment Address
34 to 39
Note1: This adjustment should be carried out upon completion of “Color
reproduction adjustments”.
Note2: After the power is turned on, this adjustment can be done only
once.
Note3: Check that the data of page: 6, address: 02 is “00”. If not, to page:
6, address: 01, set data: 00, and press the PAUSE button.
Switch setting:
1)
NIGHT SHOT (Lens block) ............................................ OFF
2)
DIGITAL ZOOM (Menu display) ................................... OFF
3)
STEADY SHOT (Menu display) ..................................... OFF
4)
LIGHT (FK-2000 block) .................................................. OFF
Adjusting method:
Order Page Address Data
Procedure
1
0
01
01
Set the data.
2
Wait for 2 sec.
3
6
01
11
Set the data, and press PAUSE
button.
4
6
01
0D
Set the data, and press PAUSE
button
5
6
02
Check that the data changes to
“01”. (Note4)
Note4: The adjustment data will be automatically input to page: F, address:
34 to 39.
Processing after Completing Adjustments
Order Page Address Data
Procedure
1
6
01
00
Set the data, and press PAUSE
button.
2
0
01
00
Set the data.
3
Perform “Auto White Balance
Adjustment”.
Page of 127
Display

Click on the first or last page to see other CCD-TRV107 / CCD-TRV108 / CCD-TRV308 / CCD-TRV408 / CCD-TRV608 service manuals if exist.