5-24
6. White Balance Adjustment (VF-126 board)
Correct the white balance.
If deviated, the reproduction of the EVF screen may degenerate.
Mode
Camera
Subject
Arbitrary
Measurement Point
Check on EVF screen
Measuring Instrument
Adjustment Page
E
Adjustment Address
C8, C9
Specified Value
The EVF screen should not be colored.
Adjusting method:
1)
Select page: 0, address: 01, and set data: 01.
2)
Select page: 2, address: 01, set data: 51, and press the PAUSE
button of the adjustment remote commander.
3)
Select page: 2, address: 7D, and set data: 03.
4)
Select page: E, address: C5 and C6, set the data to the initial
value.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
5)
Check that the EVF screen is not colored. If colored, change
the data of page: E, address: C8 and C9 so that the EVF screen
is not colored.
Note:
To write in the non-volatile memory (EEPROM), press the
PAUSE button of the adjustment remote commander each time
to set the data.
6)
Select page: 2, address: 7D, and set data: 00.
7)
Select page: 2, address: 01, set data: 00, and press the PAUSE
button.
8)
Select page: 0, address: 01, and set data: 00.
Address
C8
C9
Data
80
80
Page of 127