CCD-TR315E, CCD-TR415E, CCD-TR425E, CCD-TR515E, CCD-TR516E, CCD-TR713E, CCD-TRV16E, CCD-TRV26E, CCD-TRV27E, CCD-TRV27EP, CCD-TRV36E, CCD-TRV46E - Sony Movie Service Manual (repair manual). Page 127

Read Sony CCD-TR315E / CCD-TR415E / CCD-TR425E / CCD-TR515E / CCD-TR516E / CCD-TR713E / CCD-TRV16E / CCD-TRV26E / CCD-TRV27E / CCD-TRV27EP / CCD-TRV36E / CCD-TRV46E Service Manual online

5-41
2. Emergency Memory Address
Contents
1st EMG code
Upper: MSW code when the mechanism starts shifting
the 1st time
Lower: MSW code when the 1st emergency occurs
Lower: Target MSW code of the 1st emergency occurs
2nd EMG code
Upper: MSW code when the mechanism starts shifting
the 2nd time
Lower: MSW code when the 2nd emergency occurs
Lower: Target MSW code of the 2nd emergency occurs
Last EMG code
Upper: MSW code when the mechanism starts shifting
the last time
Lower: MSW code when the last emergency occurs
Lower: Target MSW code of the last emergency occurs
Address
10
12
13
14
16
17
18
1A
1B
Type of Emergency
No error
Loading motor time-out during load
Loading motor time-out during unload
T reel emergency (reel slack) during unloading
S reel emergency (reel slack) during unloading
T reel emergency
S reel emergency
FG emergency at the start up of the capstan
FG emergency during the normal rotation of the capstan
FG emergency at the start up of the drum
PG emergency at the start up of the drum
FG emergency during the normal rotation of the drum
PG emergency during the normal rotation of the drum
Phase emergency during the normal rotation of the
drum
Code
00
10
11
20
21
22
23
30
31
40
41
42
43
44
Address 10 to 1B
Page F
When there are no emergency, data 00 will be written in the above
addresses (10 to 1B). When the first emergency occurs, the data
corresponding to the emergency will be written in the address (10
to 13) for this first emergency. In the same way, when the second
emergency occurs, the data corresponding to the emergency will be
written in the address (14 to 17) for this second emergency.
The data corresponding to the emergency occurring the last will be
written in the address (18 to 1B) for this last emergency.
Therefore the data of addresses 18 to 1B are renewed each time an
emergency occurs.
Note 1:
Be sure to rewrite the data of addresses 10 to 1B to 00
after repairs/adjustments.
Note 2:
When rewriting the data, be sure to press the PAUSE
buttton of the remote commander after setting the data.
2-1. EMG CODE (Emergency Code)
The codes shown in the following table which correspond to errors
that occur are recorded in addresses 10, 14, and 18.
Page of 127
Display

Download Sony CCD-TR315E / CCD-TR415E / CCD-TR425E / CCD-TR515E / CCD-TR516E / CCD-TR713E / CCD-TRV16E / CCD-TRV26E / CCD-TRV27E / CCD-TRV27EP / CCD-TRV36E / CCD-TRV46E Service Manual (Repair Manual)