ALIGNMENT PROCEDURE   
 
Equipment Required 
Computer:              PC workstation with Windows 95/98/2000 installed 
                          
     PS/2 mouse is required 
Software:
                                   
Engineering alignment software tool same as L200 
Color meter:
                             
Topcon BM-7 or equivalent 
Signal generator:
                    
VG-819 or equivalent 
Cable:
                                         
RS232 interface cable same as L200 
 
Monitor Setup 
1. Entering maintenance mode by hold the “+” & “-“ key and press power switch. 
 
Hardware Install 
1. Copy software <ALIGN.EXE> into a new PC directory.  
2. Prepare timing & pattern data full white for signal generator according to present 
timing. 
3. Prepare timing files for <ALIGN.EXE>. 
4. Connect monitor RS-232 interface cable between monitor and PC’s COM port. 
5. Connect monitor video cable to signal generator. 
6. Put Topcon BM7 50cm from the UUT; Point it perpendicularly at the center of the 
display; Achieve the best focus through the eyepiece. 
7. Enclose the UUT & Topcon BM7 in a light-shielded chamber. 
 
Software Setup 
1. Execute software <ALIGN.EXE>. 
2. Click on [Setup] menu. 
3. Select [Monitor] type as [L200]; select ‘Color Analyzer’ type & ‘Video Signal 
Generator’ type. 
4. Select [COM PORT] according to hardware connection. 
5. Click [OK] to save the new setup configuration. 
6. Quit this application and Re-enter to make the new setting effective. 
 
 
 
 
 
 
 