SDM-HX75, SDM-HX95 - Sony Monitor Service Manual (repair manual). Page 9

Read Sony SDM-HX75 / SDM-HX95 Service Manual online

EDID data for SDM- HX95 (Analog) 
Ver1.0
No. Data
No. Data
No. Data
No.
Data
0 00h <Header>
32 12h (Blue)Y
64 13h
96
44h D
1 FFh
33 50h (White)X
65 00h
97
4Dh M
2 FFh
34 54h (White)Y
66 78h
98
2Dh -
3 FFh
35 ADh <Established Timings>
67 2Dh
99
48h H
4 FFh
36 CFh
68 11h
100
58h X
5 FFh
37 00h
69 00h
101
39h 9
6 FFh
38 81h <Standard Timings>
70 00h
102
35h 5
7 00h
39 80h #1:1280*1024/60Hz
71 1Eh
103
0Ah (EOL)
8 4Dh < Manufacturer name >
40 81h
72 00h D Timing #2
104
20h
9 D9h SNY
41 40h #2:1280*960/60Hz
73 00h <Range>
105
20h  
10
00h
53h
< Product code >
42 01h
74 00h
106
20h  
11
( 0053) --> 5300
43 01h #3:None
75 FDh
107
20h  
12 01h (Un-used : Serial)
44 01h
76 00h
108
00h D Timing #4
13 01h
,,
45 01h #4:None
77 30h fV min.        48 [Hz]
109
00h <Serial Number>
14 01h
,,
46 01h
78 4Bh fV max.       75 [Hz]
110
00h <Example>
15 01h
,,
47 01h #5:None
79 1Ch fH min.        28 [kHz]
111
FFh
16 *1 <Week>
48 01h
80 51h fH max.       81 [kHz]
112
00h
17 *2 <Year>
49 01h #6:None
81 0Eh Max. p_clk   140 [MHz]
113
*3
18 01h <EDID S_Version>
50 01h
82 00h
114
*3
19 03h <EDID Revision>
51 01h #7:None
83 0Ah
115
*3
20 0Ch <Video Input siganl>
52 01h
84 20h
116
*3
21 26h <Max.H. Image Size> 376mm
53 01h #8:None
85 20h
117
*3
22 1Eh <Max.V. Image Size> 301mm
54 30h D Timing #1
86 20h
118
*3
23 78h <Gamma>
55 2Ah <Signal Timing>
87 20h
119
*3
24 EAh <DPMS etc.>
56 00h ( VESA1280x1024@60 )
88 20h
120
0Ah (EOL)
25 D8h <Color>
57 98h
89 20h
121
20h  
26 55h
58 51h
90 00h D Timing #3
122
20h  
27 A3h (RED)X
59 00h
91 00h <Model Name 1>
123
20h  
28 59h (RED)Y
60 2Ah
92 00h SDM-HX95
124
20h  
29 48h (Green)X
61 40h
93 FCh
125
20h  
30 99h (Green)Y
62 30h
94 00h
126
00h
31 24h (Blue)X
63 70h
95 53h S
127
*4
<Check Sum>
 
 
*1. Input Data according to production week. 
*2. Input Data according to production year. 
Year code = A.D.-1990 
Ex) A.D.2004-> 0Eh 
*3. Change decimal-seven-digit serial number to the ACII code and input it by unit. 
Ex) 5000001-> 35,30,30,30,30,30,31 
113 -> 35h, 114 -> 30h, 115 -> 30h, 116 -> 30h, 117 -> 30h, 118 -> 30h, 119 -> 31h 
*4. Input the data as the value of the lower 8 bits of the sum up all registers from #0 to #126 is equal to 
"00h". 
Ex) The sum of data from #0 to #126 is "1C2Bh".  In this case, the check sum is "D5h", 
2Bh+D5h=100h 
*5. Color Data of panel 
 
       
2 5
D 8 h
< C o lo r >
2 6
5 5 h
2 7
A 3 h (R E D )X = 0 .6 4 0
2 8
5 9 h
(R E D )Y = 0 .3 4 9
2 9
4 8 h
(G r e e n )X = 0 .2 8 3
3 0
9 9 h
(G r e e n )Y = 0 .5 9 8
3 1
2 4 h
(B lu e )X = 0 .1 4 2
3 2
1 2 h
(B lu e )Y = 0 .0 7 1
3 3
5 0 h
(W h it e )X = 0 .3 1 3
3 4
5 4 h
(W h it e )Y = 0 .3 2 9
F u j i t s u   p a n e l ( F L C 4 8 S X C 8 V - 1 2 )
 
- 9 -                                                      SDM-HX75/95 (E) 
Page of 20
Display

Click on the first or last page to see other SDM-HX75 / SDM-HX95 service manuals if exist.