GDM-F520 - Sony Monitor Service Manual (repair manual). Page 7

Read Sony GDM-F520 Service Manual online

— 8 —
GDM-F520
SECTION 1: DISASSEMBLY
1-1.  CABINET REMOVAL
1
B
B
A
A
C
C
Two screws
(+BVTP 4 x 16)
6
Slide the EMI shield in the direction
of arrow      and remove four claws.
7
EMI shield 
5
Three screws
(+BVTT 4 x 8)
4
Four screws
(+BVTT 4 x 8)
Two claws
3
Push the upper side of the cabinet assembly
in the direction of arrow     , disconnect claws, 
then remove the cabinet assembly
lifting it up in the direction of arrow     .
Bezel
EMI shield
Cabinet assembly
Cabinet assembly
Bezel
Push in the tip of a screwdriver
about 10mm to unlock the claw.
22
Page of 109