GDM-90W01T5 - Sony Monitor Service Manual (repair manual). Page 2

Read Sony GDM-90W01T5 Service Manual online

GDM-90W01T5
– 2 –
POWER  SAVING  FUNCTION
This monitor is capable of three states of reduced power consumption. By sensing the absence of video signals and one or both sync signals
coming from the host computer, it will reduce power consumption as follows.
Recovery time
Approx. 3 sec.
Approx. 3 sec.
Approx. 10 sec.
Power consumption
 200 W
 140 W
 15 W
 8 W
0 W
Power consumption
state
1 Normal operation
2 Standby (1st state)
3 Suspend (2nd state)
4 Active-off (3rd state)
5 Power-off
u
 power indicator
Green on
Green on
Green on
Off
Off
@
 power saving indicator
Off
Orange on
Orange on
Orange on
Off
Failure
HV, +B failure
Horizontal/Vertical deflection failure, thermal
protector
ABL protector
Aging/Self Test
Power Saving LED
Off
Blink Amber
Blink Amber
Off
Power LED
Blink Amber
Off
Blink Amber
Amber (0.5 sec) 
Off (0.5 sec) 
Green (0.5 sec) 
Off (0.5 sec) 
DIAGNOSIS
Aging Mode: Video aging
During Power Save, press “OPTION” Key for longer than 2 seconds.
Self Test: OSD color-bar indication
During Power Save, press “CONTRAST+” Key for longer than 2 seconds.
Self Test: OSD All White indication
During Poewr Save, press “COLOR” key for longer than 2 seconds.
PRIMARY MODE
PRIMARY
MODE AT PRODUCTION
MODE1
MODE2
MODE3
MODE4
MODE5
MODE6
MODE7
MODE8
MODE9
RESOLUTION
640 X 480
1280 X 1024
1600 X 1200
1920 X 1080
1920 X 1080
1600 X 1024
1920 X 1200
720 X 400
1920 X 1035
CLOCK
25.175 MHz
135.000 MHz
202.500 MHz
159.840 MHz
216.023 MHz
170.447 MHz
245.480 MHz
28.322 MHz
74.250 MHz
— HORIZONTAL —
H-FREQ
31.469 kHz
79.976 kHz
93.750 kHz
67.500 kHz
84.384 kHz
81.320 kHz
95.000 kHz
31.469 kHz
33.750 kHz
µ
sec
µ
sec
µ
sec
µ
sec
µ
sec
µ
sec
µ
sec
µ
sec
µ
sec
H. TOTAL
31.778
12.504
10.667
14.815
11.851
12.297
10.526
31.777
29.630
H. BLK
6.356
3.022
2.765
2.803
2.963
2.910
2.705
6.355
3.771
H. FP
0.636
0.119
0.316
0.200
0.222
0.188
0.261
0.636
0.593
H. SYNC
3.813
1.067
0.948
0.901
1.000
0.939
1.043
3.813
1.185
H. BP
1.907
1.837
1.501
1.702
1.741
1.784
1.401
1.907
1.993
H. ACTIV
25.422
9.481
7.901
12.012
8.888
9.387
7.821
25.422
25.859
— VERTICAL —
V. FREQ(HZ)
59.940 Hz
75.025 Hz
75.000 Hz
60.000 Hz
72.000 Hz
76.000 Hz
76.000 Hz
70.087 Hz
60.000 Hz
lines
lines
lines
lines
lines
lines
lines
lines
lines
V. TOTAL
525
1066
1250
1125
1172
1070
1250
449
562.5
V. BLK
45
42
50
45
92
46
50
49
45
V.  FP
10
1
1
3
3
3
3
12
5
V. SYNC
2
3
3
3
3
3
3
2
5
V. BP
33
38
46
39
86
40
44
35
35
V. ACTIV
480
1024
1200
1080
1080
1024
1200
400
517.5
— SYNC  —
INT(G)
NO
NO
NO
NO
NO
NO
NO
NO
NO
EXT(H/V)/POLARITY
YES N/N
YES P/P
YES P/P
YES N/N
YES N/N
YES N/N
YES N/N
YES N/P
YES N/N
EXT(CS)/POLARITY
NO
NO
NO
NO
NO
NO
NO
NO
NO
INT/NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
NON INT
INT
96.8.22 VER.
TIMING  SPECIFICATION
Page of 47