GDM-200PS, GDM-200PST, GDM-200PST9 - Sony Monitor Service Manual (repair manual). Page 13

Read Sony GDM-200PS / GDM-200PST / GDM-200PST9 Service Manual online

GDM-200PS/200PST/200PST9
2-6. PICTURE  TUBE  REMOVAL
3
When one side of the rubber cap is
separated from the anode button, the
anode-cap can be removed by turning
up the rubber cap and pulling up it in the
direction of the arrow 
c
.
• HOW  TO  HANDLE  AN  ANODE-CAP
1
Don’t hurt the surface of anode-caps with shartp shaped material!
2
Don’t press the rubber hardly not to hurt inside of anode-caps!
A material fitting called as shatter-hook terminal is built in the
rubber.
3
Don’t turn the foot of rubber over hardly!
The shatter-hook terminal will stick out or hurt the rubber.
a
b
c
Anode Button
• REMOVAL  OF  ANODE-CAP
NOTE: Short circuit the anode of the picture tube and the anode cap to the metal chassis, CRT shield or carbon painted on the CRT, after
removing the anode.
• REMOVING  PROCEDURES
1
Turn up one side of the rubber cap in
the direction indicated by the arrow 
a
.
2
Using a thumb pull up the rubber cap
firmly in the direction indicated by the
arrow 
b
.
2-3
    A board
10
     Anode cap
8
     Screw
     (+P 4 x 12)
6
     Screw
     (+P 4 x 12)
4
     Three connectors
     (CN2, 4, GND)
9
     Screw
     (+BVTT 4 x 8)
1
CN4
CN2
GND
    Stand assy
3
     Hook (17)
5
     Hook (17)
7
     Two screws
     (+BVTP 3 x 10)
11
     Four screws
     (Tapping screw 5 : U/C, SH model)
     (Self tapping  screw 5 : AEP, UK model)
12
     Chassis assy
13
     Picture tube
16
Cushion
    Two claws
2
     Deflection yoke
15
     Neck assy
14