DHC-FL3, GDM-C520, GDM-C520K, HCD-FL3 - Sony Monitor Service Manual (repair manual). Page 7

Read Sony DHC-FL3 / GDM-C520 / GDM-C520K / HCD-FL3 Service Manual online

— 8 —
GDM-C520/C520K
SECTION 1: DISASSEMBLY
1-1.  CABINET REMOVAL
1
Two screws
(+BVTP 4 x 16)
6
Slide the EMI shield in the direction
of arrow   and remove four claws.
7
EMI shield 
4
Four screws
(+BVTT 4 x 8)
5
Five screws
(+BVTT 4 x 8)
2
Two claws
Bezel
Bezel
EMI shield
Cabinet assembly
Cabinet assembly
Push in the tip of a screwdriver
about 10mm to unlock the claw.
B
A
C
3
Push the upper side of the cabinet assembly
in the direction of arrow  , disconnect claws,
then remove the cabinet assembly
lifting it up in the direction of arrow  .
C
B
A
Page of 69