Read Sony CPD-G520P (serv.man2) Service Manual online
CPD-G520P (E)
1-1
SECTION 1
DISASSEMBLY
1-1. CABINET ASSEMBLY REMOVAL
1
Two screws
(+BVTP 4 x 16)
(+BVTP 4 x 16)
6
Slide the EMI shield in the direction
of arrow
of arrow
C
and remove four claws.
7
EMI shield
4
Four screws
(+BVTT 4 x 8)
(+BVTT 4 x 8)
5
Five screws
(+BVTT 4 x 8)
(+BVTT 4 x 8)
2
Two claws
Bezel
Bezel
EMI shield
Cabinet assembly
Cabinet assembly
Push in the tip of a screwdriver
about 10mm to unlock the claw.
about 10mm to unlock the claw.
B
A
C
3
Push the upper side of the cabinet assembly
in the direction of arrow
in the direction of arrow
A
, disconnect claws,
then remove the cabinet assembly
lifting it up in the direction of arrow
lifting it up in the direction of arrow
B
.