CPD-G420S - Sony Monitor Service Manual (repair manual). Page 5

Read Sony CPD-G420S Service Manual online

CPD-G420S(E)
5
DIAGNOSIS
Failre
+B failure
Horizontal / Vertical Deflection
failure, Thermal protector
ABL protector
HV failure
Aging / Self Test
Out of scan range
Power LED
Amber
Off
(0.5 sec)
(0.5 sec)
Amber
Off
(1.5 sec)
(0.5 sec)
Amber
Off
(0.5 sec)
(1.5 sec)
Amber
Off
Amber
Off
(0.25 sec)
(0.25 sec)
(0.25 sec)
(1.25 sec)
Amber
Off
Green
Off
(0.5 sec)
(0.5 sec)
(0.5 sec)
(0.5 sec)
Green (OSD indication)
Aging Mode (Video Aging) : During Power Save, press MENU button for longer than 2 second.
Self Test (OSD Color Bar)
: During Power Save, push up Control button for longer than 2 second.
Reliability Check Mode
: During Power Save, push down Control button for longer than 2 second.
Page of 85