— 7 —
CPD-G420
1-1. CABINET REMOVAL
SECTION  1: DISASSEMBLY
1
B
B
A
A
C
C
Two screws
(+BVTP 4 x 16)
6
Slide the EMI shield in the direction
of arrow 
 and remove four claws.
7
EMI shield
4
Four screws
(+BVTT 4 x 8)
5
Four screws
(+BVTT 4 x 8)
2
Two claws
3
Push the upper side of the cabinet
inthe direction of arrow 
, disconnect claws, 
then remove the cabinet
lifting it up in the direction of arrow 
.
Bezel assembly
Bezel assembly
EMI shield
Cabinet
Cabinet
Push in the tip of a screwdriver
about 10mm to unlock the claw.