Read Sony CPD-G420 (serv.man4) Service Manual online
— 14 —
CPD-G420
SECTION 3: ADJUSTMENTS
Allow a 30 minute warm-up period prior to making the following
adjustments.
3-1. LANDING ROUGH ADJUSTMENT
1. Display the all white pattern.
2. Set contrast to 255.
3. Display plain green pattern.
4. Slide the DY back and roughly adjust the plain green pattern with
2. Set contrast to 255.
3. Display plain green pattern.
4. Slide the DY back and roughly adjust the plain green pattern with
the purity magnet so that it is centered on the screen.
5. Adjust the DY tilt.
NOTE: Set ROTATION to 128 and LCC_NS to 128 when
NOTE: Set ROTATION to 128 and LCC_NS to 128 when
adjusting the DY tilt.
6. Lightly tighten the DY screw.
3-2. LANDING FINE ADJUSTMENT
NOTE: (1) After adjusting W/B (9300k), measure the average of
ΣΙΚ
with all white video input, while CONTRAST is maximum
and BRIGHTNESS is centered. Make the adjustments so
that the miss-landing becomes least after aging 2H with
the
and BRIGHTNESS is centered. Make the adjustments so
that the miss-landing becomes least after aging 2H with
the
ΙΚ
30% of measured value shown above.
(2)
The
magnetic
Þ eld shall be BH = 0.
(3) When adjusting at other than BH = 0, calculate the shifted
value from BH = 0.
1. Place the monitor in the Helmholtz coil.
2. Set as follows;
2. Set as follows;
LCC-SW = 0 (LCC Correction Current = 0)
FUNCTION_SW bit1 = (Auto Degauss = On)
CONTRAST
=
255
3. Display plain green pattern.
4. Degauss the iron part of the chassis with a hand-degausser and
4. Degauss the iron part of the chassis with a hand-degausser and
degauss coil.
5. Degauss the CRT face with degauss equipment or hand-
degausser.
6. Input AC 230V to AC IN and turn the monitor off and on to activate
the auto degausser.
Connect the communication cable of the connector located on the D Board on the monitor. Run the service software and then follow the
instructions.
instructions.
IBM at Computer
as a Jig
1
2
3
1-690-391-21
A-1500-819-A
Interface Unit
3-702-691-01
Connector Attachment
Connector Attachment
To BUS CONNECTOR
D-Sub
(9 Pin [female])
Mini Din
(8 Pin)
4 Pin
4 Pin
4 Pin
* The Parts above ( ) are necessary for DAS Adjustment.
1
3
~
7. Reset FUNCTION_SW bit 1 to 0 (auto-degauss = off)
8
8
Repeat step 5 by degaussing the CRT face with degauss
equipment or hand-degausser.
equipment or hand-degausser.
9. Attach a wobbling coil to the speciÞ ed position of CRT neck.
10. With landing checker, adjust DY position, purity, DY center, and
10. With landing checker, adjust DY position, purity, DY center, and
landing of the 4 corners.
11. Check landing of the 4 corners, and adjust using a magnet if they
are not in the speciÞ cation.
± 6
± 6
± 6
± 6
± 6
± 6
± 6
± 6
± 6
<Specifications>
Adjust so that the green is within
the specification given right.
4 corner adjust target : within ± 1
Adjust so that the green is within
the specification given right.
4 corner adjust target : within ± 1
The red and blue must be within
the specification given right with
respect to the green.
the specification given right with
respect to the green.
A difference between red and blue
must be within the specification
given right.
must be within the specification
given right.
0 ± 3 0 ± 7.5 0 ± 3
0 ± 3 0 ± 7.5 0 ± 3
0 ± 3 0 ± 7.5 0 ± 3
(µm)
(µm)
10
10
10
10
7
10
10
10
10
(µm)
12. Tighten DY screw within speciÞ ed torque, and auto-degauss.
NOTE: Torque 22 ± 2 kgcm (2.2 ± 0.2 Nm)
13. Adjust the vertical angle of the DY to make the top and bottom
NOTE: Torque 22 ± 2 kgcm (2.2 ± 0.2 Nm)
13. Adjust the vertical angle of the DY to make the top and bottom
pins equal (a = b). The horizontal angle is not changed (straight).
Settle DY upright without leaning, and insert wedges Þ rmly so that
the DY does not move.
Settle DY upright without leaning, and insert wedges Þ rmly so that
the DY does not move.
a
b
c
d
<How to place wedge>
Green plain crosshatch pattern
Green plain crosshatch pattern
a and b should be equal.
c and d should be equal.
c and d should be equal.
Click on the first or last page to see other CPD-G420 (serv.man4) service manuals if exist.