CPD-G420 (serv.man2) - Sony Monitor Service Manual (repair manual). Page 16

Read Sony CPD-G420 (serv.man2) Service Manual online

CPD-G420
2-1. CABINET REMOVAL
SECTION  2
DISASSEMBLY
2-1
1
B
A
C
Two screws
(+BVTP 4 x 16)
6
Slide the EMI shield in the direction
of arrow 
C
 and remove four claws.
7
EMI shield
4
Four screws
(+BVTT 4 x 8)
5
Four screws
(+BVTT 4 x 8)
2
Two claws
3
Push the upper side of the cabinet
inthe direction of arrow 
A
, disconnect claws, 
then remove the cabinet
lifting it up in the direction of arrow 
B
.
Bezel assembly
Bezel assembly
EMI shield
Cabinet
Cabinet
Push in the tip of a screwdriver
about 10mm to unlock the claw.
Page of 61
Display

Click on the first or last page to see other CPD-G420 (serv.man2) service manuals if exist.