— 11 —
CPD-G220R/G220S
3-7. DIGITAL CONVERGENCE ADJUSTMENT
Convergence (Low) Mode
1.  Adjust the H.STAT and V.STAT with "HSTAT" and "VSTAT".
2.  Change "CONV_SW" to "7".
 A. 
Horizontal 
Convergence
 
Adjust each misconvergence point in sequence.
 
B. Vertical Convergence
 
Adjust each misconvergence point in sequence.
2.  Repeat the procedure of A and B so that the convergence of the 
entire screen is within the specifi cation.
Convergence (High) Mode
1.  Adjust the H.STAT and V.STAT with "HSTAT-HI" and "VSTAT-HI".
 A. 
Horizontal 
Convergence
 
Adjust each misconvergence point in sequence.
 B. 
Vertical 
Convergence
 
Adjust each misconvergence point in sequence.
2.  Repeat the procedure of A and B so that the convergence of the 
entire screen is within the specifi cation.
3.  Change "MCR2" to "170".
3-8. CONVERGENCE SPECIFICATION
        
A Zone:
Primary Mode      Others
H: < 0.25mm       H: < 0.3mm
V: < 0.25mm        V: < 0.3mm
B Zone:
Primary Mode      Others
H: < 0.3mm         H: < 0.4mm
V: < 0.3mm          V: < 0.4mm